2016
DOI: 10.17981/ingecuc.12.2.2016.08
|View full text |Cite
|
Sign up to set email alerts
|

Power distribution transformers using natural ester fluids as dielectric and coolant

Abstract: Abstract− Researches related with the use of Natural Ester Fluids as refrigerant of power transformers has been developed in other countries with successful results. In Colombia there is no a procedure to control the use of these esters in electrical apparatus, so the current implementations are regulated by NTC 1465 standards for mineral esters. This new proposal involves the composition and the most relevant properties (the ignition resistance, impact on the lifetime of the insulating papers and the impact o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 4 publications
(4 reference statements)
0
2
0
Order By: Relevance
“…As described above with cellulose paper, the technical life of natural esters depends on the raw materials from which they are made (internal factors) as well as the environment to which they are exposed (external factors). The major degradation processes of natural esters are hydrolysis [28], polymerization [29], oxidation [30], and hydrogenation [31].…”
Section: Degradation Processes In Natural Estersmentioning
confidence: 99%
“…As described above with cellulose paper, the technical life of natural esters depends on the raw materials from which they are made (internal factors) as well as the environment to which they are exposed (external factors). The major degradation processes of natural esters are hydrolysis [28], polymerization [29], oxidation [30], and hydrogenation [31].…”
Section: Degradation Processes In Natural Estersmentioning
confidence: 99%
“…To determine the state of the power quality losses at the two points evaluated, the frequency variation is initially verified according to the criteria of NTC 1340, taking measurements every 10 s and using a frequency range between 59,8 Hz and 60,2 Hz (Norma Técnica Colombiana NTC 1340 -Electrotecnia. Tensiones y Frecuencia Nominales en Sistemas de Energía Eléctrica en Redes de Servicio Público, 2013;Silva Ortega et al, 2016). Similarly, the nominal value of the voltage can be 5% above and 8% below.…”
Section: Methodsmentioning
confidence: 99%