2023
DOI: 10.1109/tie.2022.3189099
|View full text |Cite
|
Sign up to set email alerts
|

Power Electronic Converter Based Induction Motor Emulator With Stator Winding Faults

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 33 publications
0
5
0
Order By: Relevance
“…It is to be noted that the effect of the shorted turns is to reduce the effective number of turns in the winding and, consequently, the effective impedance (Equations 4 and 5). 10,11 According to Liu et al 32 and from the experimental waveforms depicted in Section 4 of this paper, it is seen that when an inter‐turn fault occurs, the current amplitude of two phases is higher (including the faulty phase) than that of the other phase.…”
Section: Mathematical Modelmentioning
confidence: 77%
See 3 more Smart Citations
“…It is to be noted that the effect of the shorted turns is to reduce the effective number of turns in the winding and, consequently, the effective impedance (Equations 4 and 5). 10,11 According to Liu et al 32 and from the experimental waveforms depicted in Section 4 of this paper, it is seen that when an inter‐turn fault occurs, the current amplitude of two phases is higher (including the faulty phase) than that of the other phase.…”
Section: Mathematical Modelmentioning
confidence: 77%
“…The three-phase motor parameters used for SITF detection with the proposed algorithm are measured by performing the no-load (NL) test, blocked rotor test, and direct current (DC) resistance test and winding resistance measurement at shutdown on the experimental motor. 32 The maximum stator winding resistances at a particular load condition can be measured just after shutdown of a motor in order to take into account the effect of the temperature rise. The rotor resistances referred to stator-side are then computed based on the DC resistance test, blocked rotor test, and the stator winding resistances measured at a particular load.…”
Section: Impedance Correction Coefficients (β-Coefficients)mentioning
confidence: 99%
See 2 more Smart Citations
“…Emulators are widely used in industry [30], [31], [32], [33] and the proposed architecture can contribute to the realization of a complete emulator for an energy production turbine. In a possible practical scenario, the proposed DRC circuit is sided by circuits for the emulation of the other sensors and actuators present onboard the generators.…”
Section: Discussionmentioning
confidence: 99%