Power Extraction Control of Variable Speed Wind Turbine Systems Based on Direct Drive Synchronous Generator in All Operating Regimes

Abstract: Due to the increased penetration of wind energy into the electrical power systems in recent years, the turbine controls are actively occupied in the research. This paper presents a nonlinear backstepping strategy to control the generators and the grid sides of a Wind Farm System (WFS) based Direct Drive Synchronous Generator (DDSG). The control objectives such as Tracking the Maximum Power (TMP) from the WFS, pitch control, regulation of dc-link voltage, and reactive and active power generation at varying wind… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 47 publications
0
5
0
Order By: Relevance
“…The mathematical modeling of the PMSG is given in the dq-axes reference frame. The stator voltage (v d and v q ) equations are given by [24][25][26]:…”
Section: Surface Permanent Magnet Synchronous Generator Modelingmentioning
confidence: 99%
See 2 more Smart Citations
“…The mathematical modeling of the PMSG is given in the dq-axes reference frame. The stator voltage (v d and v q ) equations are given by [24][25][26]:…”
Section: Surface Permanent Magnet Synchronous Generator Modelingmentioning
confidence: 99%
“…where: R s : the stator resistance; L d and L q : the d-q axis inductances; i d and i q : the stator currents in the d-q axis and ω e : the electrical speed of the generator, it is related to the mechanical speed Ω m by [24][25][26]:…”
Section: Surface Permanent Magnet Synchronous Generator Modelingmentioning
confidence: 99%
See 1 more Smart Citation
“…Nevertheless, the major problem of this type of wind turbine is the amplitude of the voltage produced at the terminals of the asynchronous generator. Frequency and the power generated depend on the connected load, the wind speed and self-excitation capacities [15][16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33].…”
Section: Introductionmentioning
confidence: 99%
“…Meanwhile an alternative way to cope efficiently with the nonlinear nature and varying operation conditions of PMSG WECS is to exploit nonlinear control designs. Accordingly feedback [16,17] and sliding mode [18][19][20][21][22][23][24][25] techniques have been successfully processed. An association of passivity theory with sliding mode control was proposed in [26] to remove the PMSG WECS nonlinearities and cope with various uncertainties.…”
Section: Introductionmentioning
confidence: 99%