2019
DOI: 10.1109/tpel.2018.2873503
|View full text |Cite
|
Sign up to set email alerts
|

Power Flow and Stability Analyses of a Multifunctional Distributed Generation System Integrating a Photovoltaic System With Unified Power Quality Conditioner

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
45
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 99 publications
(46 citation statements)
references
References 29 publications
0
45
0
1
Order By: Relevance
“…x can be achieved by using the maximum power point tracking (MPPT) controller [15]. Otherwise, when PV array is disconnected, the reference port voltage is given as…”
Section: Control Of Qab Convertermentioning
confidence: 99%
See 1 more Smart Citation
“…x can be achieved by using the maximum power point tracking (MPPT) controller [15]. Otherwise, when PV array is disconnected, the reference port voltage is given as…”
Section: Control Of Qab Convertermentioning
confidence: 99%
“…Currently, many researchers have done a lot to study the topologies of UPQC with different aims [13]. In [14]- [15], the UPQC integrated with DG system (UPQC-DG) is presented to relieve the load active power demand on the grid, while the investment cost is relatively high. In [16], the interline UPQC (UPQC-I) is proposed to control the active power flow between two feeders and mitigate the PQ issues of the two feeders, but the current-and voltage-related PQ issues are not simultaneously mitigated in the same feeder.…”
Section: Introductionmentioning
confidence: 99%
“…Non‐sinusoidal currents and voltages references have been used to control the most UPQC applications . Therefore, it is indicated to employ any method for extraction the reference quantities …”
Section: Proposed Upqc Topology Descriptionmentioning
confidence: 99%
“…To overcome the most problems related to PQ, single‐phase and three‐phase series‐parallel active power‐line conditioners, known as unified power quality conditioners (UPQC), have been employed in there‐phase three‐ and four‐wire systems (3P3W and 3P4W) by means of different configurations and control strategies.…”
Section: Introductionmentioning
confidence: 99%
“…L. B. G. Campanhol etl. [14], [15] proposes a single-stage three-phase four-wire gridconnected Photo Voltaic (PV) system operating with a dual compensating strategy and feed forward control loop, the three level Neutral Point Converter (NPC) power circuit gives lower economic cost and better output performance, while this system may results in stability problem between loads and PV system.…”
Section: Introductionmentioning
confidence: 99%