IECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Society 2016
DOI: 10.1109/iecon.2016.7793426
|View full text |Cite
|
Sign up to set email alerts
|

Power-Hardware-In-Loop harmonic analysis of a Smart Transformer-fed distribution grid

Abstract: Abstract-The Smart Transformer (ST) offers ancillary services in the low voltage grids. These new services in a real distribution grid can be demonstrated by means of simulation software, but it is difficult to prove them in lab due to the complexity and heterogeneity of the distribution grids. The PowerHardware-In-Loop (PHIL) evaluation is an interesting solution for emulating the interaction between the real grid, simulated in a Real Time Digital Simulator (RTDS), and the ST. However the PHIL evaluation requ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 14 publications
0
2
0
Order By: Relevance
“…Three different types of PA are compared in [19], and their main characteristics classification are shown in Table 1. In the case of switched amplifiers, which are non-linear interface converters, it can be useful to know what considerations have been made by the authors in every test about the accuracy and stability of PHIL [99]. To give to the reader an overview of the most important PA included in the online database, the main PA manufacturers and the published papers where they were used are listed below:…”
Section: Power Amplifiermentioning
confidence: 99%
“…Three different types of PA are compared in [19], and their main characteristics classification are shown in Table 1. In the case of switched amplifiers, which are non-linear interface converters, it can be useful to know what considerations have been made by the authors in every test about the accuracy and stability of PHIL [99]. To give to the reader an overview of the most important PA included in the online database, the main PA manufacturers and the published papers where they were used are listed below:…”
Section: Power Amplifiermentioning
confidence: 99%
“…As mentioned in the literature [10], the choice of the interface algorithm is fundamental in the accuracy and stability of the P-HIL experiments. In [11], [12] a controlled Current-Type (C-CT) P-HIL interface algorithm is proposed for ST applications, due to the grid-forming characteristics of the ST at the LV dc/ac stage. In those studies, although a first accuracy and stability assessment has been provided, the analysis is based on empirical evaluation, without any comprehensive accuracy and stability investigation.…”
Section: Introductionmentioning
confidence: 99%