Power Quality 2011
DOI: 10.5772/15996
|View full text |Cite
|
Sign up to set email alerts
|

Power Quality and Electrical Arc Furnaces

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0
4

Year Published

2017
2017
2023
2023

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(12 citation statements)
references
References 18 publications
0
8
0
4
Order By: Relevance
“…The author [8] has shown that the use of three phase power analyzer for the power quality analysis and the following quantities are important to be measured such as voltage, current, flicker (IEC 68, IEC 61000-4-15-P ST and P LT ), wave shots, THD and harmonics up to the higher orders .In different stages of operation of electrical arc furnace, the TDD-I vary between 1% -21% for the current and 1% -6% for the THD-V. Comparing the value with the international standard, it is observed that the arc furnace does not match with either national or international standard.…”
Section: Review Of Harmonic Generated By Eaf In Power Systemmentioning
confidence: 99%
“…The author [8] has shown that the use of three phase power analyzer for the power quality analysis and the following quantities are important to be measured such as voltage, current, flicker (IEC 68, IEC 61000-4-15-P ST and P LT ), wave shots, THD and harmonics up to the higher orders .In different stages of operation of electrical arc furnace, the TDD-I vary between 1% -21% for the current and 1% -6% for the THD-V. Comparing the value with the international standard, it is observed that the arc furnace does not match with either national or international standard.…”
Section: Review Of Harmonic Generated By Eaf In Power Systemmentioning
confidence: 99%
“…Only 32% of the steel factory in the world used the EAF due to its expensive cost compared to the traditional furnaces. The EAF is composed of three parts, the shell which includes walls and lower bowl, the main part and the roof part which is well insulated or water cooled [3].…”
Section: Introductionmentioning
confidence: 99%
“…A step-down transformer is normally adopted for feeding the electrodes, usually characterized by significant series impedance, which helps arc stability, provides current limitation and mitigates grid current harmonics. This solution is very robust, but suffers from several issues, especially the "pollution" of the electrical grid [1] (e.g. flicker, harmonics) and low Power Factor (PF), which require oversizing the power distribution system.…”
Section: Introductionmentioning
confidence: 99%
“…Simulation investigation, optimization and validation prior to implementation of control algorithms have been performed by reproducing the overall digital control architecture and power electronic converters, including communication constraints among different modules and controllers. Both a complete analytical model from literature on gas discharge [1], and a novel empirical one, based on measurements from an actual plant, have been used for modeling the arc voltage/current relation. Finally, experimental results will be presented for an actual EAF plant.…”
Section: Introductionmentioning
confidence: 99%