Power quality control based on voltage sag/swell, unbalancing, frequency, THD and power factor using artificial neural network in PV integrated AC microgrid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
30
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 72 publications
(31 citation statements)
references
References 48 publications
1
30
0
Order By: Relevance
“…The PI controller optimized by the genetic algorithm gives 0.89% of the total harmonic distortion (THD) less than 1.97% obtained in [22]. This value of THD satisfies the standard value given by NF C 15-100 and IEEE 519 (T HD <5%) [15], [27], [28]. Figure 12 (a) shows the deference between the proposed method and PI Classique.…”
Section: Resultssupporting
confidence: 52%
“…The PI controller optimized by the genetic algorithm gives 0.89% of the total harmonic distortion (THD) less than 1.97% obtained in [22]. This value of THD satisfies the standard value given by NF C 15-100 and IEEE 519 (T HD <5%) [15], [27], [28]. Figure 12 (a) shows the deference between the proposed method and PI Classique.…”
Section: Resultssupporting
confidence: 52%
“…From the above results, it is evident that the modular statcom with FLC-based ESOGI can eliminate current harmonics. The comparative study with the existing method clearly indicates that a harmonic distortion in the source current measured by the proposed system is 1.2%, which is below the average THD level obtained by the systems of Kausal and Basak 19 ; Piradhan and Mishra 20 ; Divyalakshmi and Subramaniam 21 ; and Prasad and Akella. 22…”
Section: Case 3: Unbalanced Non-linear Loads At Varying Wind Speedmentioning
confidence: 62%
“…In some cases, the microgrid can also present resonances at low frequencies, which might result in an undesirable increase of voltage harmonics (Bollen et al, 2017a(Bollen et al, , 2017b. According to Kaushal and Basak (2020), the effect of line impedance on power quality parameters is especially important when the microgrid's status changes from interconnected to islanded mode. As a result, voltage deviations are the main affected parameter.…”
Section: Assessment Of Power Quality Disturbances In Ac Islanded Microgridsmentioning
confidence: 99%
“…Some studies implement control strategies in order to reduce the in those kinds of microgrids. Some of the proposed strategies include adding virtual impedance (Savaghebi, Shafiee, Vasquez, and Guerrero, 2015;Golsorkhi, Lu, Savaghebi, Vasquez, and Guerrero, 2016;Yang, Chen, Dong, and Han, 2015;Micallef, Apap, Spiteri-Staines, Guerrero, 2012;Blanco, Tardelli, Reigosa, Zanchetta, and Briz, 2019), harmonic controller (Zeng, Yi, Zhai, Zhuo, and Wang, 2017;Thai, Raisz, Monti, Ponci, and Ahmadifar 2018;Dehghani, Vahedi, Savaghebi, and Guerrero, 2012), compensations (Phan and Lee, 2019) Fuzzy-PI (Lhachimi, Sayouti, and Kouari, 2020) and artificial neural network (ANN) controllers (Kaushal and Basak, 2020). Table 2 shows the variation of five islanded microgrids when different control strategies are implemented.…”
Section: Harmonics and Supraharmonicsmentioning
confidence: 99%