2020
DOI: 10.1049/iet-gtd.2019.1042
|View full text |Cite
|
Sign up to set email alerts
|

Power quality control through automated demand side management in microgrid equipped with battery energy storage for protection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 29 publications
(54 reference statements)
0
5
0
Order By: Relevance
“…To assess the load side reliability, the DSM method is given [85] which is applied to the Electrical Power Distribution System (EPDSs) to achieve the efficient reliability of the power system. On the other side of the analysis, DSM is also considered for control of microgrid considering Battery Energy Storage System (BESS), protection, and power quality issues [86]. Thus, MCS and a local load system method are developed for reliability evaluation and assessment, respectively, which incorporates DSM and wind as described in Figure 12(b).…”
Section: Reliability Improvement Methodsmentioning
confidence: 99%
“…To assess the load side reliability, the DSM method is given [85] which is applied to the Electrical Power Distribution System (EPDSs) to achieve the efficient reliability of the power system. On the other side of the analysis, DSM is also considered for control of microgrid considering Battery Energy Storage System (BESS), protection, and power quality issues [86]. Thus, MCS and a local load system method are developed for reliability evaluation and assessment, respectively, which incorporates DSM and wind as described in Figure 12(b).…”
Section: Reliability Improvement Methodsmentioning
confidence: 99%
“…The results show that the load-shifting strategy produced a promising outcome for reducing the TDD. A study [45] examined the power quality control for a microgrid via the management of battery energy system and protection using automated demand side management (ADSM). The study recommended that power quality parameter of voltage deviation, frequency, total harmonic distortion and power factor be quantified through power quality monitoring index (PQMI) and corrective action to be taken in through ADSM for the benefit of the microgrid.…”
Section: Total Harmonic Distortion Thd/total Demand Distortion Tddmentioning
confidence: 99%
“…2) The microgrid model proposed in literature [30]: the day-ahead optimization model considering energy storage battery access.…”
Section: Example Analysis Of User-side Energy Managementmentioning
confidence: 99%
“…Finally, using the estimated partial values, a TOU tariff is recommended for each group's load profile. The literature [30] found that battery energy storage (BES), smart protection and power quality are considered as independent issues. These three factors can be effectively linked by automatic demand side management (ADSM) to control the micro grid.…”
Section: Introductionmentioning
confidence: 99%