2017
DOI: 10.11591/ijece.v7i2.pp720-728
|View full text |Cite
|
Sign up to set email alerts
|

Power Quality Enhancement in Grid Connected PV Systems using High Step Up DC-DC Converter

Abstract: Renewable energy sources (RES) are gaining more importance in the present scenario due to the depletion of fossil fuels and increasing power demand. Solar energy is the one of the most promising as it is clean and easily available source. The voltage obtained from the PV system is low. This voltage is increased by high step up dc-dc converter which uses only one switch leads to low switching losses and hence the efficiency of this converter is high. To get the good response this converter is operated in closed… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 8 publications
0
9
0
Order By: Relevance
“…DC-DC converters with the right selection of Kp and Ki values and implemented on PV network systems for interconnection with inverters can help to achieve a stable neutral current and a balanced load current. This converter implementation can reduce low costs, because it uses fewer components when compared to APF techniques [2]. Converters based on active and passive network inductors with dc-dc voltage gain can work on duty cycles (D) less than 0.5.…”
Section: Introductionmentioning
confidence: 99%
“…DC-DC converters with the right selection of Kp and Ki values and implemented on PV network systems for interconnection with inverters can help to achieve a stable neutral current and a balanced load current. This converter implementation can reduce low costs, because it uses fewer components when compared to APF techniques [2]. Converters based on active and passive network inductors with dc-dc voltage gain can work on duty cycles (D) less than 0.5.…”
Section: Introductionmentioning
confidence: 99%
“…Firstly, the zero-sequence current in the three-phase four-wire system is analyzed. Three-phase current , and in the three-phase four-wire system can be expressed as the components of zero-sequence current of a, b and c are equal, so the total zero sequence current i0 in the whole system is: Relatively to the above command algorithm, the system also needs to consider the stability of DC side voltage of grid-connection converter so as to realize the basic function of photovoltaic gridconnection [19]. Therefore, a feedback loop is added after the active power flows through the LPF filter to stabilize the DC side voltage of the inverter.…”
Section: Instruction Signal Operationmentioning
confidence: 99%
“…In the current era, shortages of the energy sources, changing the global climate, and world energy conflicts lead to negative effects to all levels of the society and threatened world stability was increasing These challenges can be decreasing the fossil fuel reserves to the growth of the world population, Global climate change, and Increased in wastes levels (solid/liquid) and can be resulted to electricity crisis. Diverse strategies have been investigated and studied to generate alternative energy [1,2]. These strategies are considered significant, especially for future world stability [3,4].…”
Section: Introductionmentioning
confidence: 99%