2022
DOI: 10.1016/j.ijepes.2022.108063
|View full text |Cite
|
Sign up to set email alerts
|

Power quality enhancement of grid-islanded parallel microsources using new optimized cascaded level control scheme

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 43 publications
0
1
0
Order By: Relevance
“…The Second-Order Algorithm (SOA) dynamically adjusts the gains of the PID controller, significantly enhancing the power quality of the diesel generator system. By employing a Triple Action Controller (TAC), it is possible to achieve regulation of voltage and frequency, minimize voltage Total Harmonic Distortion (THD), and control the current flow between inverters that are parallel [33]. Implementing a TAC control approach with droop and secondary optimized parameters can effectively decrease the circulating current between the inverters and enhance power sharing .…”
Section: A Optimization Methodologiesmentioning
confidence: 99%
See 1 more Smart Citation
“…The Second-Order Algorithm (SOA) dynamically adjusts the gains of the PID controller, significantly enhancing the power quality of the diesel generator system. By employing a Triple Action Controller (TAC), it is possible to achieve regulation of voltage and frequency, minimize voltage Total Harmonic Distortion (THD), and control the current flow between inverters that are parallel [33]. Implementing a TAC control approach with droop and secondary optimized parameters can effectively decrease the circulating current between the inverters and enhance power sharing .…”
Section: A Optimization Methodologiesmentioning
confidence: 99%
“…The control mechanism enhanced the overall dependability and power consistency of the system. In order to mitigate the presence of harmonics on the Alternating Current (AC) side of a hybrid MGs, Utilized are Power Filtering Compensation (PFC) kit modules and active power filters [33].…”
Section: A Optimization Methodologiesmentioning
confidence: 99%
“…In 2022, Salem et al [25] have described the parallel multi-inverter operation of an upgraded PQ island microgrid (MG). PQ appears to be enhanced by the regulation of voltage/frequency, the elimination of all harmonic distortions, and the control of circulating current.…”
Section: Literature Surveymentioning
confidence: 99%
“…The utilization of a triple action controller (TAC) enables the voltage and frequency regulation, reduces voltage THD and the circulation of current between parallel inverters [21]. TAC system combines a feedforward current supported controller and a PR-controller with a selective harmonic compensator.…”
Section: A Optimization Techniquesmentioning
confidence: 99%