2016
DOI: 10.1109/tia.2016.2600644
|View full text |Cite
|
Sign up to set email alerts
|

Power Quality Enhancement Using DSTATCOM in Distributed Power Generation System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
8
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 66 publications
(9 citation statements)
references
References 42 publications
1
8
0
Order By: Relevance
“…The effectiveness of the control is depicted with dark green being the most effective and orange the least, and so on; SRF control is on the right side of the bowtie as a risk mitigating control. The effectiveness level of the SRF control is depicted as high in Figure 1 because of its proven and reliable application of mitigating power quality issues [14][15][16]. Moreover, our study also found that after applying the SRF control scheme of Section 2 of the paper, the risk mitigation results are promising, as presented in the results part of this paper.…”
Section: Introductionsupporting
confidence: 58%
See 1 more Smart Citation
“…The effectiveness of the control is depicted with dark green being the most effective and orange the least, and so on; SRF control is on the right side of the bowtie as a risk mitigating control. The effectiveness level of the SRF control is depicted as high in Figure 1 because of its proven and reliable application of mitigating power quality issues [14][15][16]. Moreover, our study also found that after applying the SRF control scheme of Section 2 of the paper, the risk mitigation results are promising, as presented in the results part of this paper.…”
Section: Introductionsupporting
confidence: 58%
“…Harmonics were generated due to nonlinear and undesirable load and high switching frequency of converters that affected wind generation and the overall system. B.Singh et al presented a control scheme with an SRF-and PLL-based strategy in [14][15][16]. For such power quality issues, reactive power compensation can be applied as in B.Singh et al, who depicted some control schemes for mitigation of this problem in [17][18][19].…”
Section: Introductionmentioning
confidence: 99%
“…Compared with the dq methods, the pq theory can effectively reduce the computation time without using the PLL algorithm and transferring to dq0 synchronous reference frame. Furthermore, several studies that adopt the DSTATCOM approach to improve the power quality have been proposed for industrial applications [1,8,[14][15][16]. A photovoltaic fed DSTATCOM using an optimization technique for the power quality improvement was proposed in [1].…”
Section: Introductionmentioning
confidence: 99%
“…In [8], a DSTATCOM peak detection method was proposed for the compensation in a three-phase four-wire distribution system. A distributed generator system with a DSTATCOM using a composite observer based control technique to improve the power quality was proposed in [14]. In [15], a cascaded H-bridge multilevel inverter-based DSTATCOM was developed for reactive power compensation and load balancing under linear load and unbalanced load conditions.…”
Section: Introductionmentioning
confidence: 99%
“…In addition, under low load condition, reactive power must be controlled to circumvent unacceptable voltage rise. To regulate reactive power transfer a FACTS device D-STATCOM has been utilized [4][5][6][7].…”
Section: Introductionmentioning
confidence: 99%