2020
DOI: 10.1016/j.micpro.2020.103016
|View full text |Cite
|
Sign up to set email alerts
|

Power quality improvement of solar power plants in grid connected system using novel Resilient Direct Unbalanced Control (RDUC) technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(7 citation statements)
references
References 17 publications
0
7
0
Order By: Relevance
“…The performance of the EFO-GBDT is determined subject to the output generated by the PV, wind turbine system and back up energy storage device is named as battery. 27,[29][30][31][32] Different case studies are considered to test and verify the performance of the proposed method. The three types of case studies utilized in this simulation section is, (a) under constant wind speed, the irradiance of PV is changed, (b) under constant irradiance of PV, the wind speed is varied, (c) under constant irradiance of PV and wind speed, the load fault is occurred.…”
Section: Simulation Results and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The performance of the EFO-GBDT is determined subject to the output generated by the PV, wind turbine system and back up energy storage device is named as battery. 27,[29][30][31][32] Different case studies are considered to test and verify the performance of the proposed method. The three types of case studies utilized in this simulation section is, (a) under constant wind speed, the irradiance of PV is changed, (b) under constant irradiance of PV, the wind speed is varied, (c) under constant irradiance of PV and wind speed, the load fault is occurred.…”
Section: Simulation Results and Discussionmentioning
confidence: 99%
“…In this control scheme, the optimal dataset is generated by the EFOA technique as well as the optimal control signal is generated by the GBDT technique. The performance of the EFO‐GBDT is determined subject to the output generated by the PV, wind turbine system and back up energy storage device is named as battery 27,29‐32 . Different case studies are considered to test and verify the performance of the proposed method.…”
Section: Simulation Results and Discussionmentioning
confidence: 99%
“…The p-q theory is used, which is mainly based on a-b-c conversion into α-β-0 coordinates and α-β-0 conversation into a-b-c parameters, which are familiarly known as Clark's transformation and inverse transformation, respectively (Durairasan and Balasubramanian, 2020;Hari Prabhu and Sundararaju, 2020;Sureshkumar and Ponnusamy, 2020). The transformation is shown in Figures 6, 7, from which compensating currents are generated.…”
Section: Hybrid Shunt Active Power Filter Control Structurementioning
confidence: 99%
“…Three-phase supply voltages are V Sa , V Sb , and V Sc , whereas the phase-neutral voltages are V Sα , V Sβ . The instantaneous values of actual and unconsidered powers are determined using phase neutral voltages and load currents (Hari Prabhu and Sundararaju, 2020;Sureshkumar and Ponnusamy, 2020). In the shunt active filter, the actual and reactive power is determined using the below equation (Dashtdar et al, 2021a)…”
Section: Hybrid Shunt Active Power Filter Control Structurementioning
confidence: 99%
“…Where Il, Il are phase neutral currents and I La , I Lb , I Lc are three-phase load currents, respectively. V Sa , V Sb , and V Sc are three-phase supply voltages, whereas V Sα , V Sβ , are phaseneutral voltages [25][26][27][28][29][30]. The real and unconsidered powers of instantaneous values are calculated using phase neutral voltages and load currents.…”
Section: Control Structure Of Shunt Active Power Filtermentioning
confidence: 99%