2013 IEEE 39th Photovoltaic Specialists Conference (PVSC) 2013
DOI: 10.1109/pvsc.2013.6744492
|View full text |Cite
|
Sign up to set email alerts
|

Power quality survey of a photovoltaic power plant

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
2
0
1

Year Published

2014
2014
2021
2021

Publication Types

Select...
3
2

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 27 publications
1
2
0
1
Order By: Relevance
“…This is an additional contribution of the paper, providing an alternative characterisation of real disturbances and a complete comparison with the current grid-code requirements, in terms of both voltage value limits and time intervals. Actually, and in line with other recent contributions of the authors, the severity of the faults is highly dependent on the voltage evolution along the disturbance and the point-on-wave initiation [19,31].…”
Section: Research Articlesupporting
confidence: 77%
“…This is an additional contribution of the paper, providing an alternative characterisation of real disturbances and a complete comparison with the current grid-code requirements, in terms of both voltage value limits and time intervals. Actually, and in line with other recent contributions of the authors, the severity of the faults is highly dependent on the voltage evolution along the disturbance and the point-on-wave initiation [19,31].…”
Section: Research Articlesupporting
confidence: 77%
“…Voltage Dips. Among the PQ voltage variation phenomena, the voltage dips are the most common [15], [22], [23]. Voltage dips are characterized by the duration and the residual voltage [14].…”
Section: A Measurement Of Pq Phenomenamentioning
confidence: 99%
“…In [16], more than half of the recorded voltage dips has a time duration less than or equal to 5 cycles and 80 % has a residual voltage in the range between 70 % and 90 %. In [22], most of the events (about 94 %) present a residual voltage equal to 70 % to 90 % and their durations range between 0 ms and 100 ms (5 cycles of 50 Hz). Also, in [24] about 60 % of the voltage dips measured in a 22 kV substation has a residual voltage between 70 % and 90 % and time durations lower than 100 ms.…”
Section: A Measurement Of Pq Phenomenamentioning
confidence: 99%
“…Normalmente se emplean diagramas tridimensionales para representar grácamente los eventos, asignando a cada las variables tensión ecaz residual, duración del hueco y número de eventos respectivamente. Una vía alternativa para sintetizar y mostrar las perturbaciones se encuentra propuesta en [119]. Este tipo de representación, llamado mapa de colores, clasica las perturbaciones en sectores rectangulares.…”
Section: Nuevas Propuestas De Caracterizaciónunclassified