2018 IEEE PES/IAS PowerAfrica 2018
DOI: 10.1109/powerafrica.2018.8520992
|View full text |Cite
|
Sign up to set email alerts
|

Power System Static Security Enhancement Through Interline Power Flow Controller

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 12 publications
0
5
0
Order By: Relevance
“…Two indices are presented for contingency ranking in References 24,25, which use the performance index of power (PIP) and performance index of voltage for security assessment, as stated in (11) and (12). The PIP index is already used in References 26‐29. Compared to the presented indices in previous studies for line flows, which had been based on apparent power, this equation addressed the power index based on active power flow and the lines priority, which is shown by the coefficient W : PIp=l=1Nl()W2nPlPlmax2n, PIV=l=1Nb()W2nViVispnormalΔVilim2n. …”
Section: Categorization Based On Power System Implementationmentioning
confidence: 99%
See 1 more Smart Citation
“…Two indices are presented for contingency ranking in References 24,25, which use the performance index of power (PIP) and performance index of voltage for security assessment, as stated in (11) and (12). The PIP index is already used in References 26‐29. Compared to the presented indices in previous studies for line flows, which had been based on apparent power, this equation addressed the power index based on active power flow and the lines priority, which is shown by the coefficient W : PIp=l=1Nl()W2nPlPlmax2n, PIV=l=1Nb()W2nViVispnormalΔVilim2n. …”
Section: Categorization Based On Power System Implementationmentioning
confidence: 99%
“…In Reference 29, flexible alternating current transmission equipment such as interline power flow controller (IPFC) has been used for static security improvement of the grid. Different comparisons between compensated (with IPFC) and uncompensated (without IPFC) in different scenarios have been presented.…”
Section: Special Casesmentioning
confidence: 99%
“…Static security specifes the security of the power system at a steady state after the occurrence of an outage of a line, a transformer, a generator, or a load from the system. Contingency could be defned as failure of the system components, such as transmission line-related problems, which could be caused due to overloading or mal-operation of the transmission network, which leads the system component to fail [2]. Te contingency analysis (CA) could be employed by the operators to assess the system security under component failures and to decide whether control actions are needed [3].…”
Section: Introductionmentioning
confidence: 99%
“…Te efectiveness of series compensation had been demonstrated in controlling line power fow and improving stability [4]. An IPFC, which comprises multiple voltage source converters (VSCs), is one of the FACTS devices having the capacity of compensating for both real and reactive power fow through multiple transmission lines [2].…”
Section: Introductionmentioning
confidence: 99%
“…Each of quadratic subproblems optimizes a quadratic model of objective function subject to the linearization of constraints and are solved by creating iterative steps. SQP is appropriate for small and large problems especially problems with significant nonlinearities [12,13]. Minimizing a nonlinear programming problem of the form.…”
mentioning
confidence: 99%