2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings 2012
DOI: 10.1109/i2mtc.2012.6229173
|View full text |Cite
|
Sign up to set email alerts
|

Practical design of low-cost instrumentation for industrial electrical impedance tomography (EIT)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
21
0
2

Year Published

2013
2013
2022
2022

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(24 citation statements)
references
References 2 publications
1
21
0
2
Order By: Relevance
“…The EIT prototypes proposed by the scientific community are integrated with analog components and control devices [97], especially used in the processes of signal generation, measurement and processing. This is how proposals are based on FPGA [5], [34], [36], [98], [99], DSP [91], [100] and Microcontrollers [39], [40], which present modular architectures. Although they have sufficient characteristics for particular medical applications, these proposals have limitations such as the calibration of the modules for generating sinusoidal signals, reconfiguration of injection patterns and measurement of signals, which may require a hardware reconfiguration [101], [102].…”
Section: Discussionmentioning
confidence: 99%
“…The EIT prototypes proposed by the scientific community are integrated with analog components and control devices [97], especially used in the processes of signal generation, measurement and processing. This is how proposals are based on FPGA [5], [34], [36], [98], [99], DSP [91], [100] and Microcontrollers [39], [40], which present modular architectures. Although they have sufficient characteristics for particular medical applications, these proposals have limitations such as the calibration of the modules for generating sinusoidal signals, reconfiguration of injection patterns and measurement of signals, which may require a hardware reconfiguration [101], [102].…”
Section: Discussionmentioning
confidence: 99%
“…3.1) injects a constant amplitude, low frequency sinusoidal current electrical current through the driving electrodes and the boundary voltages are measured on the sensing electrodes with four electrode method [28,209] using an electronic instrumentation [13,14,20,25,32,125,164,176]. For a current injection through a particular current electrode pair, the boundary voltage current data are collected from all voltage electrode pairs excluding the pairs containing one or two current electrodes.…”
Section: Electrical Impedance Tomography (Eit)mentioning
confidence: 99%
“…The quality of the reconstructed images is also good. [1] Z. Zhou et.al proposed a telemedicine system based on EIT which is fast and portable. The proposed system can be used for monitoring the health status of out-of-hospital patients.…”
Section: Related Workmentioning
confidence: 99%