Pre-analytical sample handling standardization for reliable measurement of metabolites and lipids in LC-MS-based clinical research

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(18 citation statements)
references
References 56 publications
0
15
0
Order By: Relevance
“…Prostanoid levels were measured as previously described (Sens et al, 2023) with slight adaptions for the analysis of tissue samples. Briefly, tissues were homogenized by wet bead milling using zirconium oxide beads in 2‐ml reinforced tubes (Bertin Instruments, Frankfurt, Germany) and a Precellys 24‐Dual with a Cryolys cooling module (Bertin Instruments) as previously described (Kratz et al, 2022).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Prostanoid levels were measured as previously described (Sens et al, 2023) with slight adaptions for the analysis of tissue samples. Briefly, tissues were homogenized by wet bead milling using zirconium oxide beads in 2‐ml reinforced tubes (Bertin Instruments, Frankfurt, Germany) and a Precellys 24‐Dual with a Cryolys cooling module (Bertin Instruments) as previously described (Kratz et al, 2022).…”
Section: Methodsmentioning
confidence: 99%
“…Prostanoid levels were measured as previously described (Sens et al, 2023) with slight adaptions for the analysis of tissue samples.…”
Section: Prostanoid Measurementmentioning
confidence: 99%
“…Bioactive lipids including sphingolipids and ceramides, lysophosphatidic acids, endocannabinoids, eicosanoids (oxylipins) and pterins were analyzed in plasma by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) as described in detail in the supplementary material of a previous study [8]. Analytical methods were optimized based on methods reported in our previous studies [9,[51][52][53][54].…”
Section: Targeted Analyses Of Lipid Signaling Moleculesmentioning
confidence: 99%
“…The analysis of endocannabinoids was performed by adapting a method that was originally developed for the analysis of plasma samples. Briefly, cell pellets were resuspended in 200 µL of water and extracted using liquid-liquid-extraction as previously described in detail [83].…”
Section: Liquid Chromatography-tandem Mass Spectrometrymentioning