2018
DOI: 10.1016/j.nucengdes.2018.04.015
|View full text |Cite
|
Sign up to set email alerts
|

Pre-test analysis of accidental transients for ALFRED SGBT mock-up characterization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 13 publications
(14 citation statements)
references
References 6 publications
0
14
0
Order By: Relevance
“…Some TCs were added using the information derived from the pre-test analysis (Narcisi et al, 2018), based on the RELAP5-3D model (Narcisi et al, 2017) experimental validated using the ICE tests (Tarantino et al, 2015) and adapted for the HERO test section. As highlighted during the pre-tests, the fitting volume offers a large non-insulated surface for the heat losses; in order to quantify the heat dissipations, five TCs were added on the outer surface of the fitting volume.…”
Section: Figure 2 View Of the Heater Component (Top Left) The Seconmentioning
confidence: 99%
See 2 more Smart Citations
“…Some TCs were added using the information derived from the pre-test analysis (Narcisi et al, 2018), based on the RELAP5-3D model (Narcisi et al, 2017) experimental validated using the ICE tests (Tarantino et al, 2015) and adapted for the HERO test section. As highlighted during the pre-tests, the fitting volume offers a large non-insulated surface for the heat losses; in order to quantify the heat dissipations, five TCs were added on the outer surface of the fitting volume.…”
Section: Figure 2 View Of the Heater Component (Top Left) The Seconmentioning
confidence: 99%
“…At this purpose, a detailed temperature measuring system has been adopted inside the pool, as shown in Figure 3(a). Three additional TCs were set for increasing measurement points at the expected thermal stratification level, obtained with RELAP5-3D calculation during the pre-test activity (Narcisi et al, 2018). Regarding the 10 bubble tubes, six of them are connected to 3 differential pressure transmitters for measuring P: in the Venturi flow meter (inlet and throat section), between LBE free level in the pool and separator and across the lower spacer grid of the FPS.…”
Section: Figure 2 View Of the Heater Component (Top Left) The Seconmentioning
confidence: 99%
See 1 more Smart Citation
“…One of the main tasks of the experimental campaign is to investigate relevant three-dimensional phenomena within the LBE pool; for this purpose, 119 TCs are installed inside the pool in 9 azimuthal positions (the support rods are identified from A to I in Figure 3) and several axial levels that cover the whole height of the facility. The acquisition of LBE temperature is intensified in two sectors: at the level of the fitting volume, where large heat losses occur, and at the top level of the HS active length, where a thermal stratification phenomenon was expected (Narcisi et al, 2018).…”
Section: Circe-hero Test Facility 21 Description Of the Test Facilitymentioning
confidence: 99%
“…The CIRCE-HERO nodalization scheme, developed for the pre-test calculations (Narcisi et al, 2018), was improved starting from the information obtained during the blind phase of the benchmark exercise. The MULTID modelling approach was adopted for the LBE pool and a detailed mono-dimensional nodalization scheme was developed for the primary flow path and for the secondary loop.…”
Section: Introductionmentioning
confidence: 99%