Preanalytical management: serum vacuum tubes validation for routine clinical chemistry

Abstract: IntroductionThe validation process is essential in accredited clinical laboratories. Aim of this study was to validate five kinds of serum vacuum tubes for routine clinical chemistry laboratory testing.Materials and methods:Blood specimens from 100 volunteers in five diff erent serum vacuum tubes (Tube I: VACUETTE®, Tube II: LABOR IMPORT®, Tube III: S-Monovette®, Tube IV: SST® and Tube V: SST II®) were collected by a single, expert phlebotomist. The routine clinical chemistry tests were analyzed on cobas® 6000… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
13
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 33 publications
(13 citation statements)
references
References 26 publications
0
13
0
Order By: Relevance
“…No clinically significant differences were observed with use of the reformulated tube types; it thus appeared that the reformulated BD tubes had been successfully adjusted to reduce assay interference and yield results that were similar to those of glass and Vacuette tubes for the total triiodothyronine (TT 3 ), total thyroxine (TT 4 ), and cortisol assays tested [2,5]. However, further studies by Wang et al [6] and Lima-Oliveira et al [7], as well as recent TT 3 , TT 4 , and cortisol results from patients’ specimens in the author’s clinical laboratory have indicated that BD blood collection tube related interference in some clinical assays may not be fully resolved.…”
Section: Introductionmentioning
confidence: 99%
“…No clinically significant differences were observed with use of the reformulated tube types; it thus appeared that the reformulated BD tubes had been successfully adjusted to reduce assay interference and yield results that were similar to those of glass and Vacuette tubes for the total triiodothyronine (TT 3 ), total thyroxine (TT 4 ), and cortisol assays tested [2,5]. However, further studies by Wang et al [6] and Lima-Oliveira et al [7], as well as recent TT 3 , TT 4 , and cortisol results from patients’ specimens in the author’s clinical laboratory have indicated that BD blood collection tube related interference in some clinical assays may not be fully resolved.…”
Section: Introductionmentioning
confidence: 99%
“…17-hydroxyprogesterone, and aldosterone) ( 22 ). Furthermore, both serum- and lithium heparin-vacuum tubes with gel separator produced by different companies showed different laboratory results for clinical chemistry tests ( 23 , 24 ). Before adopting and standardizing every kind of in vitro devices (i.e.…”
Section: Discussionmentioning
confidence: 99%
“…Presently in order to start a ''light-side'' period in the preanalytical phase and in patient safety, the attention of the laboratory professionals has been focused on some procedures previously regarded as consolidated, such as: (i) furniture changes among different manufacturers of syringes for blood gas analyses, which can represent new sources of laboratory variability; similar considerations apply to not validated vacuum tubes [28][29][30][31]; (ii) transport boxes unable to guarantee the maintenance of the temperature during blood specimens transportation [32]; (iii) traditionally accepted although incorrect paradigms ranging from the filling of vacuum tubes to the mixing procedures which appear unsupported by accurate experimental verification; e.g., recently it has been observed that there is no apparent need to mix all blood specimens after collection into vacuum tube systems by venipuncture [33,34]. On the other hand, apparently incorrect vigorous mixing of the primary blood vacuum tubes immediately after collection does not promote laboratory variability [35]; more so, no clinical impact has been observed in routine and specialized coagulation laboratory testing when the vacuum tubes are incompletely filled (when filled more than 90 % but \100 %) [36].…”
Section: Discussionmentioning
confidence: 99%