Precisão da medida do limiar anaeróbio por meio do calorímetro portátil

Abstract: Background: Many methods are used for determining the Anaerobic Threshold (AT) by means of sophisticated ergospirometer.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

1
3
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 38 publications
1
3
0
Order By: Relevance
“…Granja Filho et al (1) observed an intra-individual variation index of 5.5% for the O 2max . Nogueira and Pompeu (21) and Magrani and Pompeu (31) observed satisfactory indices for the measurements analysed in equipment used in this study. There are differences in the measures obtained by this equipment when they are compared with the ones derived from more sophisticated equipments (3.8% versus 5.5%), the ergospirometer here adopted was validated by another group (16) and is widely applied in Brazilian laboratories.…”
Section: Discussionsupporting
confidence: 57%
See 1 more Smart Citation
“…Granja Filho et al (1) observed an intra-individual variation index of 5.5% for the O 2max . Nogueira and Pompeu (21) and Magrani and Pompeu (31) observed satisfactory indices for the measurements analysed in equipment used in this study. There are differences in the measures obtained by this equipment when they are compared with the ones derived from more sophisticated equipments (3.8% versus 5.5%), the ergospirometer here adopted was validated by another group (16) and is widely applied in Brazilian laboratories.…”
Section: Discussionsupporting
confidence: 57%
“…Descriptive statistics through mean ± mean standard error (MSE) was applied. The mean of the results obtained by the two evaluators from the EqV and V-slope methods was considered as the AT (21) . The mean of the two investigators was also used the PCR.…”
Section: Discussionmentioning
confidence: 99%
“…The measurements quality control should be assured through calibration, operation and assessment procedures conducted by experienced technicians (23) . Tests in which these care measures are taken present low variation in the repeated measurements in close moments (15)(16)(17)23,24) . The intra-individual daily variation, due to error and physiological fluctuations of VO 2 , V E and HR are (24) respectively 3.8%, 8.0% and 3.0%.…”
Section: Discussionmentioning
confidence: 99%
“…Tests in which these care measures are taken present low variation in the repeated measurements in close moments (15)(16)(17)23,24) . The intra-individual daily variation, due to error and physiological fluctuations of VO 2 , V E and HR are (24) respectively 3.8%, 8.0% and 3.0%. Granja Filho et al (17) observed intra-individual variation index of 5.5% for the VO 2max .…”
Section: Discussionmentioning
confidence: 99%