2009
DOI: 10.1016/j.molstruc.2008.08.015
|View full text |Cite
|
Sign up to set email alerts
|

Precise ground state molecular parameters of chloromethane

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
18
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 16 publications
(19 citation statements)
references
References 25 publications
1
18
0
Order By: Relevance
“…It is appropriate to mutually compare the chlorine quadrupole constants determined for the 12 and 13 isotopologues. In our recent study [6] on the 12 methyl chloride, we derived eQq 0 = À74.7631 (35) and À58.9096 (26) MHz for the 35 and 37 isotope, respectively, and the very good agreement between the quadrupole constants of the same chlorine nuclei can be seen comparing with the values in Tables 1 and 2. This agreement is a consequence of the Born-Oppenheimer theoretical presumptions, which assume the uniform molecular geometry and gradient of electrostatic potential (electron density).…”
supporting
confidence: 52%
See 2 more Smart Citations
“…It is appropriate to mutually compare the chlorine quadrupole constants determined for the 12 and 13 isotopologues. In our recent study [6] on the 12 methyl chloride, we derived eQq 0 = À74.7631 (35) and À58.9096 (26) MHz for the 35 and 37 isotope, respectively, and the very good agreement between the quadrupole constants of the same chlorine nuclei can be seen comparing with the values in Tables 1 and 2. This agreement is a consequence of the Born-Oppenheimer theoretical presumptions, which assume the uniform molecular geometry and gradient of electrostatic potential (electron density).…”
supporting
confidence: 52%
“…The optical path length of a conventional glass 280 cm long cell was doubled using a roof top mirror and a polarization grid as described in [6,7]. The sample pressures were measured by a capacitance gauge from Leybold with relative uncertainty about 5%.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The measurements were made in the frequency range between 90 and 672 GHz with the Prague semiconductor millimetre-wave high resolution spectrometer. This spectrometer was described in previous papers [6][7][8]. Frequency modulation was used with the second harmonic lock-in detection.…”
Section: Methodsmentioning
confidence: 99%
“…1) and the semiconductor millimeter wave high resolution spectrometer [19,20] at ICT in Prague. The microwave radiation is synthesized using a swept signal generator 83650 B (Agilent) operating from 10 MHz to 50 GHz.…”
Section: Methodsmentioning
confidence: 99%