2021
DOI: 10.1049/gtd2.12243
|View full text |Cite
|
Sign up to set email alerts
|

Precision enhancement of the traditional sub‐synchronous analysis by using frequency components of instantaneous magnetic flux

Abstract: Sub-synchronous resonance (SSR) is a great danger to the stable and safe operation of the synchronous generator and power network. Detecting this condition in a fast and precise method is very important for power engineers. During the last decade, many methods have been proposed for SSR detection. The most famous of these methods use shaft speed analysis. On the other hand, it is noteworthy that SSR is a phenomenon that needs the use of both mechanical and electrical quantities for its analysis. Therefore, if … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 43 publications
0
3
0
Order By: Relevance
“…Due to the limited number of datasets from field-recorded SSO cases, the commonly used IEEE first benchmark model for SSO study [3,5,6,[25][26][27] is utilized in order to analyze the performance of the proposed method. A similar model (IEEE second benchmark model) has been used in [10,12,18,28,29] to prove the effectiveness of the presented methods. The power system model is shown in Figure 5, where a 575 V is generated with a 50 Hz synchronous frequency ( f s ).…”
Section: Power System Modelmentioning
confidence: 99%
See 2 more Smart Citations
“…Due to the limited number of datasets from field-recorded SSO cases, the commonly used IEEE first benchmark model for SSO study [3,5,6,[25][26][27] is utilized in order to analyze the performance of the proposed method. A similar model (IEEE second benchmark model) has been used in [10,12,18,28,29] to prove the effectiveness of the presented methods. The power system model is shown in Figure 5, where a 575 V is generated with a 50 Hz synchronous frequency ( f s ).…”
Section: Power System Modelmentioning
confidence: 99%
“…Both the current and voltage signals are required. In [18], the authors proposed the use of frequency analysis of the magnetic flux linkage of the generator as an electrical signal along with the shaft speed as a mechanical signal to detect the SSO. This method consumes 0.6 s to discover the SSO.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation