2008
DOI: 10.1103/physrevd.78.032010
|View full text |Cite
|
Sign up to set email alerts
|

Precision measurement of the muon decay parametersρandδ

Abstract: The TWIST Collaboration has performed new measurements of two of the parameters that describe muon decay: , which governs the shape of the overall momentum spectrum, and , which governs the momentum dependence of the parity-violating decay asymmetry. This analysis gives the results ¼ 0:750 14 AE 0:000 17ðstatÞ AE 0:000 44ðsystÞ AE 0:000 11ðÞ, where the last uncertainty arises from the correlation between and the decay parameter , and ¼ 0:750 67 AE 0:000 30ðstatÞ AE 0:000 67ðsystÞ. These are consistent with the… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
31
0

Year Published

2010
2010
2014
2014

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 25 publications
(33 citation statements)
references
References 26 publications
(26 reference statements)
2
31
0
Order By: Relevance
“…The array of low mass chambers was installed in a frame referred to as the cradle, filled with helium to further reduce the amount of material traversed by the muons and positrons. Two different target foils were used over two run periods to study the effects of the target material on the decay parameters measurement: a (30:9 AE 0:6) m thick silver foil and the (71:6 AE 0:5) m thick aluminum foil used for the intermediate TWIST measurement [8]. Both metal targets had purity exceeding 99.999% and featured minimal depolarization of the muons after stopping [14].…”
Section: Experimental Setup a Twist Spectrometermentioning
confidence: 99%
See 2 more Smart Citations
“…The array of low mass chambers was installed in a frame referred to as the cradle, filled with helium to further reduce the amount of material traversed by the muons and positrons. Two different target foils were used over two run periods to study the effects of the target material on the decay parameters measurement: a (30:9 AE 0:6) m thick silver foil and the (71:6 AE 0:5) m thick aluminum foil used for the intermediate TWIST measurement [8]. Both metal targets had purity exceeding 99.999% and featured minimal depolarization of the muons after stopping [14].…”
Section: Experimental Setup a Twist Spectrometermentioning
confidence: 99%
“…We studied the stability of the decay parameters with respect to the definition of the regions by varying by a few percent all the fiducial boundaries. These boundaries were slightly modified for this analysis compared to the ones used for the intermediate measurement [8].…”
Section: Muon Decay Parameter Fitmentioning
confidence: 99%
See 1 more Smart Citation
“…From the global analysis of muon decay measurements [16], the lower bound on g can be obtained without imposing discrete symmetry as follows: (15) The new gauge boson mass M W 0 is severely constrained from K L À K S mixing if the model has manifest [6]. Instead, if we take the following form of V R , the limit on M W 0 may be significantly relaxed to approximately 300 GeV, and the W 0 boson contributions to B dðsÞ " B dðsÞ mixings can be large [18]:…”
Section: The Left-right Modelmentioning
confidence: 99%
“…Intermediate TWIST results have already reduced those uncertainties to ð0:7-3:8Þ Â 10 À3 [6,7]. TWIST has now realized its goal of making about an order of magnitude improvement in each of the parameters.…”
mentioning