2013
DOI: 10.1016/s0022-3913(13)60008-6
|View full text |Cite
|
Sign up to set email alerts
|

Precision of fit between implant impression coping and implant replica pairs for three implant systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(12 citation statements)
references
References 17 publications
0
11
0
1
Order By: Relevance
“…Prior work has demonstrated that greater dimensional variation in the machining tolerances during manufacturing produces a more asymmetric connection (Binion, 1996b;Nicoll et al, 2013). Machining tolerances in implant dentistry have been reported in the literature to range from 1 to 120 μm (do Nascimento et al, 2012;Ma et al, 1997;Nicoll et al, 2013), representing a wide variability that influences the fit of prosthetic components and the mechanical stability of the entire implant system (Binion, 1996b;Nicoll et al, 2013). To understand the effect of loading on implant systems, internal connection implant systems were exposed to rotational, vertical, and horizontal forces.…”
Section: Discussionmentioning
confidence: 99%
“…Prior work has demonstrated that greater dimensional variation in the machining tolerances during manufacturing produces a more asymmetric connection (Binion, 1996b;Nicoll et al, 2013). Machining tolerances in implant dentistry have been reported in the literature to range from 1 to 120 μm (do Nascimento et al, 2012;Ma et al, 1997;Nicoll et al, 2013), representing a wide variability that influences the fit of prosthetic components and the mechanical stability of the entire implant system (Binion, 1996b;Nicoll et al, 2013). To understand the effect of loading on implant systems, internal connection implant systems were exposed to rotational, vertical, and horizontal forces.…”
Section: Discussionmentioning
confidence: 99%
“…In a clinical situation, after applying the final torque, superstructure inaccuracy can be revealed in the form of occlusal interferences or changes in the tightness of proximal contacts. [ 12 13 ] In the present study, the frameworks were seated with controlled constant pressure, whereas in the oral cavity when the superstructure is commonly placed with finger or biting pressure on corresponding abutments, marginal gap may decrease due to increased seating force. Nevertheless, this may result in strain development within components or inadequate passive fit.…”
Section: Discussionmentioning
confidence: 99%
“…Nevertheless, this may result in strain development within components or inadequate passive fit. [ 12 13 ]…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Analizowany jest w koronach na podbudowie metalowej licowanych ceramiką [1], koronach ceramicznych [18], koronach ceramicznych z tlenku cyrkonu stabilizowanego itrem [2]. Metody oceny dokładności odwzorowania koron i filarów polegają na fizycznych pomiarach odwzorowań wnętrza podbudowy z wykorzystaniem wycisku woskowego i pomiarach filara protetycznego [3,5], wykorzystują technikę skanowania modeli referencyjnych i replik [2,3,19,20], analizę dopasowania korony z wykorzystaniem mikro CT [10] lub CT [21] oraz analizę kształtu z wykorzystaniem światła strukturalnego [4,5]. Jednak żadna z tych metod nie wykorzystuje bezstronnego narzędzia -oceny dopasowania w automatycznej procedurze numerycznej wolnej od błędów związanych z osobą wykonującą pomiar.…”
Section: Omówienie I Dyskusjaunclassified