2021
DOI: 10.1007/s00784-021-04127-9
|View full text |Cite
|
Sign up to set email alerts
|

Precision of orthodontic cephalometric measurements on ultra low dose-low dose CBCT reconstructed cephalograms

Abstract: Objectives To analyze differences in variation of orthodontic diagnostic measurements on lateral cephalograms reconstructed from ultra low dose-low dose (ULD-LD) cone beam computed tomography (CBCT) scans (RLC) as compared to variation of measurements on standard lateral cephalograms (SLC), and to determine if it is justifiable to replace a traditional orthodontic image set for an ULD-LD CBCT with a reconstructed lateral cephalogram. Material and methods U… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
18
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(19 citation statements)
references
References 25 publications
1
18
0
Order By: Relevance
“…However, both examiners had ICC medians for all three types of cephalometric analysis methods higher than 0.75, indicating that all methods had good (between 0.75 and 0.9) to excellent (greater than 0.9) intra-examiner reliability [ 34 ]. The ICCs are similar to or higher than those reported in previous publications by other groups [ 37 , 38 , 39 , 40 ], demonstrating consistency and accuracy of the present study.…”
Section: Discussionsupporting
confidence: 91%
See 2 more Smart Citations
“…However, both examiners had ICC medians for all three types of cephalometric analysis methods higher than 0.75, indicating that all methods had good (between 0.75 and 0.9) to excellent (greater than 0.9) intra-examiner reliability [ 34 ]. The ICCs are similar to or higher than those reported in previous publications by other groups [ 37 , 38 , 39 , 40 ], demonstrating consistency and accuracy of the present study.…”
Section: Discussionsupporting
confidence: 91%
“…In addition, an ultra-low-dose CBCT imaging system has also been introduced in the dental field [ 44 , 45 ]. Excitingly, outside the range of 2 mm or degrees, there is no statistical difference in performing cephalometric analysis on the full-volume CBCTs taken under the ultra-low-dose protocol and standard protocol [ 38 , 45 ]. However, it has been noted that measurements based on images taken with the standard protocol have significantly smaller standard deviations than those taken with the ultra-low-dose protocol [ 38 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The main goal of cephalometric landmarking is to perform linear and angular measurements that will ultimately provide clinical guidance. In order to evaluate the clinical usefulness of our DL-based method, our outcome set included lateral cephalometric measurements commonly found in R&R studies (van Bunningen et al 2022) as well as 3 additional frontal measurements. We chose to perform 2D cephalometric measurements based on orthogonally projected landmarks because 3D cephalometric analysis remains complex and thus beyond the scope of this study (Gateno et al 2011).…”
Section: Discussionmentioning
confidence: 99%
“…The main goal of cephalometric landmarking is to perform linear and angular measurements which will ultimately provide clinical guidance. In order to evaluate the clinical usefulness of our DL-based method, our outcome set included lateral cephalometric measurements commonly found in R&R studies (van Bunningen et al 2022) as well as three additional frontal measurements. We chose to perform 2D cephalometric measurements based on orthogonally projected landmarks because 3D cephalometric analysis remains complex, and thus beyond the scope of this study (Gateno et al 2011).…”
Section: Discussionmentioning
confidence: 99%