2020
DOI: 10.1136/neurintsurg-2019-015548
|View full text |Cite
|
Sign up to set email alerts
|

Preclinical evaluation of the ANCD thrombectomy device: safety and efficacy in a swine clot model

Abstract: BackgroundThe Advanced Thrombectomy System (ANCD) provides a new funnel component designed to reduce clot fragmentation and facilitate retrieval in patients with stroke by locally restricting flow, allowing distal aspiration in combination with a stent retriever (SR).ObjectiveTo evaluate the preclinical efficacy and safety of the ANCD in a swine clot model.MethodsSoft and firm clots were implanted in the lingual and cervical arteries of 11 swine to obtain Thrombolysis in Cerebral Infarction (TICI) 0 blood flow… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 14 publications
0
3
0
Order By: Relevance
“…In in vitro phantom and swine models of the human neurovascular anatomy, the ANA device showed better recanalization rates than SR in combination with a distal aspiration catheter or a balloon guiding catheter. 9 , 10 A preliminary first in human report indicated promising results in terms of safety and efficacy. 11 …”
mentioning
confidence: 99%
See 1 more Smart Citation
“…In in vitro phantom and swine models of the human neurovascular anatomy, the ANA device showed better recanalization rates than SR in combination with a distal aspiration catheter or a balloon guiding catheter. 9 , 10 A preliminary first in human report indicated promising results in terms of safety and efficacy. 11 …”
mentioning
confidence: 99%
“…In in vitro phantom and swine models of the human neurovascular anatomy, the ANA device showed better recanalization rates than SR in combination with a distal aspiration catheter or a balloon guiding catheter. 9,10 A preliminary first in human report indicated promising results in terms of safety and efficacy. 11 The SOLONDA study (Solitaire in Combination With the ANA Catheter System as Manufactured by Anaconda) aimed to assess the safety and performance of the ANA catheter system combined with a SR in acute ischemic stroke.…”
mentioning
confidence: 99%
“…Most recently, a novel type of aspiration catheter has been introduced. The Anaconda advanced thrombectomy system (Biomed) is an aspiration catheter system that comprises a delivery catheter and a novel funnel-shaped aspiration catheter which can expand to fit the size of the vessel it is deployed in ( 44 ). The funnel shape is achieved by a stent mounted at and covered by the distal end of the catheter, which is deployed and can expand up to a maximum of 5 mm diameter, thus providing flow arrest for vessels of this size or smaller.…”
Section: Devicesmentioning