2021
DOI: 10.1007/s00464-021-08819-x
|View full text |Cite
|
Sign up to set email alerts
|

Preclinical evaluation of the new EDGE SP 1000 single-port robotic surgical system in gynecology minimal access surgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 13 publications
0
7
0
Order By: Relevance
“…Previous experimental results have demonstrated the feasibility and safety of this new platform in the porcine model in urologic and gynaecologic surgery. 18,19 This is the first study to report its clinical practice of it in gynaecology, which demonstrates its technical feasibility and safety.…”
Section: Discussionmentioning
confidence: 79%
See 1 more Smart Citation
“…Previous experimental results have demonstrated the feasibility and safety of this new platform in the porcine model in urologic and gynaecologic surgery. 18,19 This is the first study to report its clinical practice of it in gynaecology, which demonstrates its technical feasibility and safety.…”
Section: Discussionmentioning
confidence: 79%
“…It has a single robotic arm that delivers three flexible instruments and a three‐dimensional (3D) high‐resolution camera for operation and visibility in a narrow working space. The feasibility and safety of this system in urological and gynaecological procedures in the porcine model have been proved 18,19 . Here, we report our initial experience regarding the use of the EDGE SP1000 surgical system in the clinical evaluation in a single institution.…”
Section: Introductionmentioning
confidence: 97%
“…The surgeon console has two control handles, a foot switch, multiple foot pedals, and two master manipulators. It integrates three wrist-type manipulator arms and a flexible camera manipulator arm [83]. The description of its structure and the only published preclinical study using a porcine model to perform an SP total hysterectomy lacks detailed information, although its features seem quite similar to the Da Vinci SP® platform [83].…”
Section: Edge Sp1000mentioning
confidence: 99%
“…The preclinical development of different systems has been reported in different settings. Senhance® reported its initial development in a dry laboratory [28,59,62,63], Revo-I and Senhance® performed preclinical studies using porcine models [18,21,50,95,96], Versius® was developed using porcine and cadaveric models [97][98][99][100][101][102][103][104], EDGE SP1000 reported one study done in a porcine model [83], Flex® used cadaveric and ex vivo models [85]; EDGE and Hominis® did not report any information on this topic.…”
Section: Studiesmentioning
confidence: 99%
“…This included: risk assessment of communications security, predictive analysis of security risks, implementing access control policies to enhance the security of solution, and auditing of the solution against security, safety and privacy guidelines and regulations. A limited approach to some issues of CS was addressed in a few studies, such as in surgical applications [ 23 ] or in the rehabilitation of the lower limbs [ 24 ].…”
Section: The Position Of the Care Robots In The Studiesmentioning
confidence: 99%