2016
DOI: 10.4236/oalib.1102954
|View full text |Cite
|
Sign up to set email alerts
|

Predicting the Enthalpy of Vaporization and Calculating the Entropy of Vaporization of 87 Octane Gasoline Using Vapor Pressure

Abstract: The vapor pressure (VP) of 87 grade gasoline was measured using an enhanced VP acquisition system over a temperature range of approximately 19.0˚C (292.2 K) and 69.0˚C (342.2 K). The empirical data were used to predict the thermodynamic entities the enthalpy of vaporization (ΔH vap) and the entropy of vaporization (ΔS vap) of gasoline. The results of this investigation yielded a ΔH vap value of 35.1 kJ/mol and ΔS vap of 102.5 J/mol•K. The value of ΔH vap was in excellent agreement with the findings of a prior … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(17 citation statements)
references
References 14 publications
0
16
0
Order By: Relevance
“…Hence, it is an old technique that has stood the test of time since the basis design has been upgrade on numerous occasions to be a more efficient method for collecting VP data. The fundamental apparatus for the instrument consists of a boiler, condenser, heating source for the boiler, thermometer, vacuum, and manometer. ,,, The ebulliometer employed in this research consisted of a 250 mL round-bottom (rb) flask as the boiler in which a reflux condenser was connected. The boiler served as the reservoir for the VOCs under investigation.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…Hence, it is an old technique that has stood the test of time since the basis design has been upgrade on numerous occasions to be a more efficient method for collecting VP data. The fundamental apparatus for the instrument consists of a boiler, condenser, heating source for the boiler, thermometer, vacuum, and manometer. ,,, The ebulliometer employed in this research consisted of a 250 mL round-bottom (rb) flask as the boiler in which a reflux condenser was connected. The boiler served as the reservoir for the VOCs under investigation.…”
Section: Methodsmentioning
confidence: 99%
“…18 It is important to note that water is our primary calibration/reference liquid for the VPAS and was also in prior work. 1,2 Nonetheless, the water VP data in this investigation are unique to this work.…”
Section: Evaluating the Reliability Of The Vpas From The δH Vap Of Watermentioning
confidence: 99%
See 2 more Smart Citations
“…Accurate vapor pressure data for volatile organic hydrocarbons, such as n -octane, are required when modeling industrial chemical reactions in the vapor phase that produce energy or target chemicals . Applications of automotive and aviation fuels and many catalytic processes need these data to achieve optimum performance.…”
Section: Descriptions Of the Remote Laboratoriesmentioning
confidence: 99%