1999
DOI: 10.2116/analsci.15.549
|View full text |Cite
|
Sign up to set email alerts
|

Prediction of Measurement Precision by Chemometric Invalidation of Flow Pulsation in Refractive Index Detection of Liquid Chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2003
2003
2022
2022

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 31 publications
0
2
0
Order By: Relevance
“…In a previous study, we showed that ISO 11843-7 has been applied to repeatability assessments in gas chromatography-mass spectrometry (GC-MS), high-performance liquid chromatography with UV detection (HPLC-UV), electrochemical detection (HPLC-ECD), and refractive index detection (HPLC-RI). [17][18][19][21][22][23] It has yet to be demonstrated whether ISO 11843-7 can be applied to assess repeatability in LC-MS/MS and determine an RSD of a peak area on an MRM chromatogram. If repeatability assessments for MRM chromatograms can be provided by ISO 11843-7, experimental time, effort, and chemical amounts required would be saved in the validation of an LC-MS/MS system.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In a previous study, we showed that ISO 11843-7 has been applied to repeatability assessments in gas chromatography-mass spectrometry (GC-MS), high-performance liquid chromatography with UV detection (HPLC-UV), electrochemical detection (HPLC-ECD), and refractive index detection (HPLC-RI). [17][18][19][21][22][23] It has yet to be demonstrated whether ISO 11843-7 can be applied to assess repeatability in LC-MS/MS and determine an RSD of a peak area on an MRM chromatogram. If repeatability assessments for MRM chromatograms can be provided by ISO 11843-7, experimental time, effort, and chemical amounts required would be saved in the validation of an LC-MS/MS system.…”
Section: Introductionmentioning
confidence: 99%
“…In a previous study, we showed that ISO 11843‐7 has been applied to repeatability assessments in gas chromatography–mass spectrometry (GC–MS), high‐performance liquid chromatography with UV detection (HPLC‐UV), electrochemical detection (HPLC‐ECD), and refractive index detection (HPLC‐RI) 17–19,21–23 . It has yet to be demonstrated whether ISO 11843‐7 can be applied to assess repeatability in LC–MS/MS and determine an RSD of a peak area on an MRM chromatogram.…”
Section: Introductionmentioning
confidence: 99%