2021
DOI: 10.1007/s00202-021-01224-6
|View full text |Cite
|
Sign up to set email alerts
|

Predictive current control of FL-shunt active power filter for dynamic and heterogeneous load compensation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 29 publications
0
2
0
Order By: Relevance
“…Providing custom power services with diverse power quality can flexibly meet the demands of users and improve the economic operation of the power grid (Brenna et al, 2009;Liang et al, 2022). At present, the custom power services for power quality control including voltage sag, harmonics, and voltage deviation, are mostly using the specific power quality control equipment, such as dynamic voltage restorer (Bae et al, 2010;Kumar and Tyagi, 2021), active power filter (Azhagesan et al, 2021), unified power quality regulator (Krishna et al, 2022), and static VAR compensator (Zaidan and Toos, 2021). The energy storage converter has the four-quadrant high-efficiency operation characteristics of bidirectional active and reactive power regulation.…”
Section: Introductionmentioning
confidence: 99%
“…Providing custom power services with diverse power quality can flexibly meet the demands of users and improve the economic operation of the power grid (Brenna et al, 2009;Liang et al, 2022). At present, the custom power services for power quality control including voltage sag, harmonics, and voltage deviation, are mostly using the specific power quality control equipment, such as dynamic voltage restorer (Bae et al, 2010;Kumar and Tyagi, 2021), active power filter (Azhagesan et al, 2021), unified power quality regulator (Krishna et al, 2022), and static VAR compensator (Zaidan and Toos, 2021). The energy storage converter has the four-quadrant high-efficiency operation characteristics of bidirectional active and reactive power regulation.…”
Section: Introductionmentioning
confidence: 99%
“…Four-wire APF is an ideal device to solve the problem of current distortion and excessive neutral-wire current [1][2][3], and the topology of fourwire APF can be divided into three-leg and four-leg. Four-leg APF has strong neutral-wire current compensation ability, simple dc-link voltage control, and low capacitance requirement [4], [5], so it has a broader application prospect. Three-level APF (TL-APF) provide superior performance, e.g.., low dv/dt at the output voltage, low ripples, low harmonic content current, etc., as compared to two-level APF [6].…”
Section: Introductionmentioning
confidence: 99%
“…The active filter injects active and reactive power supply with the aid of DC conversion system. It is operated with a proposed hybrid backpropagation controller [11][12][13][14]. C.K.…”
Section: Introductionmentioning
confidence: 99%