2019
DOI: 10.1111/jocs.14383
|View full text |Cite
|
Sign up to set email alerts
|

Predictors and outcomes of patient‐prosthesis mismatch after transcatheter aortic valve replacement

Abstract: Background: Patient-prosthesis mismatch (PPM) has been shown to be associated with adverse outcomes after surgical aortic valve replacement. There is limited data on its risk and impact after transcatheter aortic valve replacement (TAVR), especially with the newer generation heart valves.Objectives: The objective of this study is to investigate the incidence, predictors, and clinical outcomes of PPM after TAVR.Methods: This is a retrospective study of 991 consecutive patients who underwent TAVR procedure at a … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(12 citation statements)
references
References 24 publications
0
11
0
Order By: Relevance
“…89 The effect of mismatch on postoperative outcomes after TAVR is still controversial. 90 We performed a pooling analysis of six articles including 3358 patients (763 with patient prosthesis mismatch and 2595 without patient prosthesis mismatch) to reveal the impact of mismatch on the risk of permanent maker implantation after TAVR (Table 7). As is shown in Figure 10, the combined OR was 0.88 (95% CI: 0.67-1.16) without significant heterogeneity (I 2 = 0.0%, 95% CI: 0.0%-74.6%, p = .874).…”
Section: The Impact Of Postoperative Patient Prosthesis Mismatch On Post-tavr Ppmi Riskmentioning
confidence: 99%
“…89 The effect of mismatch on postoperative outcomes after TAVR is still controversial. 90 We performed a pooling analysis of six articles including 3358 patients (763 with patient prosthesis mismatch and 2595 without patient prosthesis mismatch) to reveal the impact of mismatch on the risk of permanent maker implantation after TAVR (Table 7). As is shown in Figure 10, the combined OR was 0.88 (95% CI: 0.67-1.16) without significant heterogeneity (I 2 = 0.0%, 95% CI: 0.0%-74.6%, p = .874).…”
Section: The Impact Of Postoperative Patient Prosthesis Mismatch On Post-tavr Ppmi Riskmentioning
confidence: 99%
“…Previous studies have also shown that smaller ES3 valves are associated with a higher incidence of sPPM [10,[16][17][18]22].…”
Section: Es Xt and Es3 Valvesmentioning
confidence: 84%
“…The latter was felt to be due to the new design and the introduction of the smaller valve size (i.e., 20 mm). Previous studies had also shown that smaller ES3 valves are associated with a higher incidence of sPPM [10,[16][17][18]22]. In our study, statistically significant differences were noted between ES XT and ES3 with regards to peak (14.6 ± 5.3 vs. 19.8 ± 8.6 mmHg, p < 0.0001) and mean (7.1 ± 2.7 vs. 10.2 ± 4.7 mmHg, p < 0.0001) trans-prosthetic gradients as well as the dimensionless index (0.57 ± 0.14 vs. 0.52 ± 0.12, p = 0.0008).…”
Section: Es Xt and Es3 Valvesmentioning
confidence: 87%
“…For first-time AVR procedures, POAF/AFL has been associated with worse mortality, higher rates of stroke, increased length of stay, and readmission [10,16,18,30,31] . Historically, the impact of POAF/AFL in r-AVR patients has not been similarly investigated.…”
Section: Discussionmentioning
confidence: 99%