2017
DOI: 10.19102/icrm.2017.081203
|View full text |Cite
|
Sign up to set email alerts
|

Predictors of Elevated Defibrillation Threshold with the Subcutaneous Implantable Cardioverter-defibrillator

Abstract: ABSTRACT. There are limited data regarding defibrillation thresholds (DFTs) for the subcutaneous implantable cardioverter-defibrillator (S-ICD), and factors associated with elevated DFTs remain incompletely understood. The objective of this study was to determine the factors associated with elevated DFTs in patients undergoing S-ICD implantation. A retrospective cross-sectional analysis of all patients undergoing S-ICD implantation at our institution between 2013 and 2016 who underwent step-down DFT testing wa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
17
3

Year Published

2018
2018
2020
2020

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 18 publications
(20 citation statements)
references
References 16 publications
0
17
3
Order By: Relevance
“…Moreover, we did not confirm the previously reported association between left ventricle wall thickness and defibrillation success 12 : our study is indeed more powered to assess the role of hypertrophy, because 33% of our patients had hypertrophic cardiomyopathy (the six with wall thickness in the 30-41 mm range had successful VF termination with ≤30 J), and the mean wall thickness of the whole population was 16 ± 8 mm, well above other literature reports. [3][4][5][6][7][8]12,13 As described by Friedman et al, 13 severely decreased ejection fraction was associated to a lower defibrillation safety margin also in our experience. However, defibrillation was successful at low shock energies even in patients with ejection fraction ≤35% in intermuscular implants, failure at ≤40 J being more common in the setting of a subcutaneous device placement.…”
Section: Discussioncontrasting
confidence: 84%
See 2 more Smart Citations
“…Moreover, we did not confirm the previously reported association between left ventricle wall thickness and defibrillation success 12 : our study is indeed more powered to assess the role of hypertrophy, because 33% of our patients had hypertrophic cardiomyopathy (the six with wall thickness in the 30-41 mm range had successful VF termination with ≤30 J), and the mean wall thickness of the whole population was 16 ± 8 mm, well above other literature reports. [3][4][5][6][7][8]12,13 As described by Friedman et al, 13 severely decreased ejection fraction was associated to a lower defibrillation safety margin also in our experience. However, defibrillation was successful at low shock energies even in patients with ejection fraction ≤35% in intermuscular implants, failure at ≤40 J being more common in the setting of a subcutaneous device placement.…”
Section: Discussioncontrasting
confidence: 84%
“…A thinner body habit enables to place both the subcutaneous coil and the generator directly over the fascia without underlying fat tissue, thus resulting in lowered energy requirement to terminate VF. Moreover, we did not confirm the previously reported association between left ventricle wall thickness and defibrillation success: our study is indeed more powered to assess the role of hypertrophy, because 33% of our patients had hypertrophic cardiomyopathy (the six with wall thickness in the 30‐41 mm range had successful VF termination with ≤30 J), and the mean wall thickness of the whole population was 16 ± 8 mm, well above other literature reports . As described by Friedman et al, severely decreased ejection fraction was associated to a lower defibrillation safety margin also in our experience.…”
Section: Discussioncontrasting
confidence: 71%
See 1 more Smart Citation
“…This patient had several features characteristic of patients known to have high DFT, including young age, male gender, severely dilated left ventricle, and nonischemic cardiomyopathy . Furthermore, high BMI has been shown to be a predictor of failed DFT testing in patients implanted with S‐ICD . His device was subsequently extracted without incident and a conventional left prepectoral transvenous ICD was implanted.…”
Section: Discussionmentioning
confidence: 99%
“…Although the procedural duration was longer compared to the conventional technique, this is still a very early experience with the procedure. As with any newly introduced technique, there is a learning curve that needs to be overcome after which the procedure duration is expected to decrease to that like other implantation techniques of S‐ICD …”
Section: Discussionmentioning
confidence: 99%