Predictors of paravalvular leak following implantation of the ACURATE neo transcatheter heart valve: the PREDICT PVL study

Abstract: ObjectivesReport predictors and the natural course of paravalvular leak (PVL) following implantation of the ACURATE neo transcatheter heart valve (THV).BackgroundUnderstanding the mechanisms of PVL may help to improve patient selection, patient outcomes and the design of next-generation THVs.MethodsA total of 30 patients (mean age 81±5 years, 47% women) undergoing transcatheter aortic valve replacement with the ACURATE neo were enrolled in the PREDICT PVL study. The effective regurgitant orifice area (EROA, in… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 14 publications
0
4
0
1
Order By: Relevance
“…Data were analyzed using a commercially available post‐processing software (Merlin, Phoenix‐PACS). Calcification of the aortic valve leaflets and left ventricular outflow tract (LVOT) were visually assessed on a scale from 0 to 3 (none, mild, moderate, extensive) 12 …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Data were analyzed using a commercially available post‐processing software (Merlin, Phoenix‐PACS). Calcification of the aortic valve leaflets and left ventricular outflow tract (LVOT) were visually assessed on a scale from 0 to 3 (none, mild, moderate, extensive) 12 …”
Section: Methodsmentioning
confidence: 99%
“…Calcification of the aortic valve leaflets and left ventricular outflow tract (LVOT) were visually assessed on a scale from 0 to 3 (none, mild, moderate, extensive). 12 All Sentinel CPS devices were deployed by experienced operators trained in TAVR, radial access, and coronary interventions. TAVR was performed via transfemoral access whenever possible, with local anesthesia under conscious sedation.…”
Section: Study Procedures and Definition Of Outcomesmentioning
confidence: 99%
“…TAVI-planning CT was obtained in all patients with a Flash Dual Source scanner, Siemens Somatom Definition Flash (Siemens Medical, Erlangen, Germany) with ECG triggering in retrospective mode as previously described. 6 , 7 The phase between 30% and 70% of the heart rate was recorded and reconstruction was performed during systole as well as diastole. The complete data set was transferred to a dedicated postprocessing workstation, measurements and analyses were performed with a commercially available software (Merlin, Phoenix-PACS, Freiburg, Germany).…”
Section: Methodsmentioning
confidence: 99%
“…This study was conducted 5 years ago. Since then the incidence of PVL, post‐TAVI, has decreased significantly over time; with improvements in transcatheter heart valve technology and implementation of an outer skirt that creates better annular sealing 15 …”
Section: Introductionmentioning
confidence: 99%