2001
DOI: 10.1053/joms.2001.20492
|View full text |Cite
|
Sign up to set email alerts
|

Preliminary investigation of the biomechanics of internal fixation of sagittal split osteotomies with miniplates using a newly designed in vitro testing model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
25
0
12

Year Published

2008
2008
2021
2021

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 63 publications
(37 citation statements)
references
References 31 publications
0
25
0
12
Order By: Relevance
“…Alberts et al 19 studied the osseous strain pattern of the maxilla after Le fort I osteotomy and suggested that FEA had more advantages than the synthetic model analysis. Note, however, that Armstrong et al 20 cited its limitations based on an in vitro experiment. In this study, we hypothesized that the maxilla is of a homogenous, isotropic, and linearly elastic structure although it has various biomechanical characteristics.…”
Section: Kyoung In Yun Et Al: a Comparison Of Fixation Methods Using mentioning
confidence: 99%
“…Alberts et al 19 studied the osseous strain pattern of the maxilla after Le fort I osteotomy and suggested that FEA had more advantages than the synthetic model analysis. Note, however, that Armstrong et al 20 cited its limitations based on an in vitro experiment. In this study, we hypothesized that the maxilla is of a homogenous, isotropic, and linearly elastic structure although it has various biomechanical characteristics.…”
Section: Kyoung In Yun Et Al: a Comparison Of Fixation Methods Using mentioning
confidence: 99%
“…Tests were carried out in an MTS 858 MiniBionix tester, using the loading confi guration proposed by Armstrong [6] and a system for three-point bending (Fig. 4).…”
Section: Methodsmentioning
confidence: 99%
“…4) fl exural rigidity is calculated from the following general relation: The models used in the tests were denoted as follows: P1 -the physiologically and anatomically normal model, P2 -the model with an osteosynthesis made with screws, P3 -the model with an osteosynthesis made with a 4-hole plate, P4 -the model with an osteosynthesis made with a 6-hole plate. [6] a b…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Um modelo de três pontos, desenvolvido previamente num estudo permitiu a formação da curva carga versus deslocamento, além de gerar medidas reproduzíveis dos limites elásticos que puderam ser comparadas entre os diferentes tipos de fixação (Armstrong et al 2001). O referido modelo apresenta um ponto de carregamento com dois apoios, ou seja, um apoio na região dos côndilos, outro na região anterior, e por último, a carga é aplicada na região de ângulo mandibular onde se inserem as fibras do músculo masseter.…”
Section: Resultsunclassified