2002
DOI: 10.1016/s0886-3350(01)01121-x
|View full text |Cite
|
Sign up to set email alerts
|

Preliminary results of cataract extraction with implantation of a single-piece AcrySof intraocular lens

Abstract: Initial results indicate that the single-piece AcrySof SA30AL IOL has good biocompatibility, haptic flexibility and resistance, and stability in the capsular bag. The incidence of PCO in 1 eye could have been the result of several factors and requires further evaluation. An area of future study is the wide haptic of the lens, which may create a path for cells to proliferate as they travel from the equatorial capsule.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
22
1

Year Published

2004
2004
2017
2017

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 31 publications
(24 citation statements)
references
References 8 publications
1
22
1
Order By: Relevance
“…This could cause a loss of barrier function to migrating lens epithelial cells, which may worsen PCO inhibition. [25][26][27][28] In the present study, there was no significant difference in PCO from 3 to 5 years after surgery. We believe that the existing migratory lens epithelial cells at the optic-haptic junction or beneath the IOL optic create a tight barrier effect against the posterior capsule preventing the migration of lens epithelial cells towards central visual axis.…”
Section: A C C E P T E D Accepted Manuscriptcontrasting
confidence: 55%
“…This could cause a loss of barrier function to migrating lens epithelial cells, which may worsen PCO inhibition. [25][26][27][28] In the present study, there was no significant difference in PCO from 3 to 5 years after surgery. We believe that the existing migratory lens epithelial cells at the optic-haptic junction or beneath the IOL optic create a tight barrier effect against the posterior capsule preventing the migration of lens epithelial cells towards central visual axis.…”
Section: A C C E P T E D Accepted Manuscriptcontrasting
confidence: 55%
“…[6][7][8] Although we expected to find interference with the blue-yellow test by the yellow chromophore of AcrySof Natural IOL, our data did not support this hypothesis.…”
Section: Discussionmentioning
confidence: 76%
“…The modified L-loop haptics are described as stable-force haptics and are made of the same hydrophoduring surgery were not uncommon because of the elasticity of the anterior lens capsule in infants and bic acrylic biomaterial. 19 The loop memory of the StableForce haptics in an AcrySof IOL have not been young children. This may at least partly alter the outcome of the capsulorhexis ovaling.…”
Section: Resultsmentioning
confidence: 99%