Preliminary survey of the electromagnetic interference environment in hospitals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
2
0
3

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(5 citation statements)
references
References 3 publications
0
2
0
3
Order By: Relevance
“…O primeiro deles, o Hospital Alfa, é classificado como diagnóstico Tipo IIA, pois mostrou uma situação bastante delicada em relação a fontes eletromagnéticas externas, mesmo quando todos os EEM estavam em repouso. Tal característica vai ao encontro de conclusões alcançadas por outros trabalhos, que destacam a importante influência de fontes externas, como sinais de rádios FM, TV e de te lefonia celular, no ambiente interno ao EAS (Arnofsky et al, 1995;Boisvert et al, 1991;Cabral e Mühlen, 2002;Davis et al, 1997Davis et al, , 1998Phaiboon e Somkuarnpanit, 2000;Vlach et al, 1995;Young et al, 1997).…”
Section: Resultsunclassified
“…O primeiro deles, o Hospital Alfa, é classificado como diagnóstico Tipo IIA, pois mostrou uma situação bastante delicada em relação a fontes eletromagnéticas externas, mesmo quando todos os EEM estavam em repouso. Tal característica vai ao encontro de conclusões alcançadas por outros trabalhos, que destacam a importante influência de fontes externas, como sinais de rádios FM, TV e de te lefonia celular, no ambiente interno ao EAS (Arnofsky et al, 1995;Boisvert et al, 1991;Cabral e Mühlen, 2002;Davis et al, 1997Davis et al, , 1998Phaiboon e Somkuarnpanit, 2000;Vlach et al, 1995;Young et al, 1997).…”
Section: Resultsunclassified
“…Last mentioned features of the fiber-optic sensors can be useful to manufacturers, during design and construction of medical equipments, in order to reduce the effects due to EMI (e.g. occurring during magnetic resonance imaging [31], electrosurgery [32], electrocardiography [33], electromyography [34] and other biomedical fields [35]) as well as to improve electrical safety conditions (prescribed by the standard IEC 60601-1 on medical equipment). Moreover, the operating principle of our OFSs (flow and differential pressure sensors) is based on the detection of the illumination pattern of emitting optical fibers, allowing the development of a system not sensitive to optical power fluctuations.…”
Section: Measurement Science and Technologymentioning
confidence: 99%
“…After verification of interferences in medical equipments, the following studies [3], [4] focused on characterizing the electromagnetic environment of hospitals. Most of the studies measured high-frequency electric field levels and identified the influence of sources outside the hospital, especially those related to communication systems such as radio and TV broadcasters, and mobile telephony.…”
Section: Introductionmentioning