2017
DOI: 10.1007/s10008-017-3635-y
|View full text |Cite
|
Sign up to set email alerts
|

Preparation and characterization of nickel hexacyanoferrate films for the removal of cesium ion by electrically switched ion exchange (ESIX)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 29 publications
0
5
0
Order By: Relevance
“…The change in one electron process (Ni 2+ /Ni 3+ ) in the electrocatalytic reaction as described in Figure S7 may also support the formation of NiO, which differs from NiO 2 and Ni 3 O 4 where the changes in electron are 2 and 0.67, respectively. Apart from this evidence, the additional peak couples at 660 and 620 mV of Ni-LCNFs in ferri/ferrocyanide solution shown in Figure S8 also postulated the formation of NiO during laser exposure, as Ni 2+ generally participated in the generation of nickel hexacyanoferrate (NiHCF) complex (Ni 2+ + K 3 Fe­(CN) 6 → KNiFe­(CN) 6 + 2K + ) . A further detailed discussion with respect to the formation of NiHCF can be found in the Supporting Information (Figure S8).…”
Section: Resultsmentioning
confidence: 83%
See 2 more Smart Citations
“…The change in one electron process (Ni 2+ /Ni 3+ ) in the electrocatalytic reaction as described in Figure S7 may also support the formation of NiO, which differs from NiO 2 and Ni 3 O 4 where the changes in electron are 2 and 0.67, respectively. Apart from this evidence, the additional peak couples at 660 and 620 mV of Ni-LCNFs in ferri/ferrocyanide solution shown in Figure S8 also postulated the formation of NiO during laser exposure, as Ni 2+ generally participated in the generation of nickel hexacyanoferrate (NiHCF) complex (Ni 2+ + K 3 Fe­(CN) 6 → KNiFe­(CN) 6 + 2K + ) . A further detailed discussion with respect to the formation of NiHCF can be found in the Supporting Information (Figure S8).…”
Section: Resultsmentioning
confidence: 83%
“…Apart from this evidence, the additional peak couples at 660 and 620 mV of Ni-LCNFs in ferri/ferrocyanide solution shown in Figure S8 also postulated the formation of NiO during laser exposure, as Ni 2+ generally participated in the generation of nickel hexacyanoferrate (NiHCF) complex (Ni 2+ + K 3 Fe(CN) 6 → KNiFe(CN) 6 + 2K + ). 31 A further detailed discussion with respect to the formation of NiHCF can be found in the Supporting Information (Figure S8). Treating the electrode with 40 CV cycles resulted in the increased peak currents until they became saturated.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The restriction on building materials for gamma radiation is based on a dose range of 0.3 -1 mSv/y. To examine whether a building material meets these limits of dose criteria, the gamma activity concentration index Iγ is calculated from the following equation [33,34]:…”
Section: Gamma Activity Index Iγmentioning
confidence: 99%
“…According to this dose criterion, materials with Iγ ≥ six should be avoided. In contrast, these values correspond to dose rates higher than one mSv/y, the highest dose rate value in air recommended for the population [9,33].…”
Section: Gamma Activity Index Iγmentioning
confidence: 99%