2020
DOI: 10.1038/s41598-020-65592-y
|View full text |Cite
|
Sign up to set email alerts
|

Preparation and characterization of novel MWCNTs/Fe-Co doped TNTs nanocomposite for potentiometric determination of sulpiride in real water samples

Abstract: Novel multiwalled carbon nanotubes/ Fe-Co doped titanate nanotubes nanocomposite (MWCNTs/Fe-Co doped TNTs) facilitated the charge transfer and enhanced sensitivity and selectivity. Herein, three novel modified carbon paste sensors (CPSs) based on MWCNTs (sensor I), Fe-Co doped TNTs (sensor II) and MWCNTs/Fe-Co doped TNTs composite (sensor III) were fabricated for a simple, low cost and high accuracy electrochemical method for the potentiometric determination of sulpiride (SLP). The sensors exhibited excellent … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 55 publications
0
6
0
1
Order By: Relevance
“…Finally, references [ 76 , 203 , 204 , 205 ] address the topic of emerging contaminants with electrochemical sensors based on CNT modified carbon electrodes, through the angle of drugs and hormones [ 76 , 203 ] and of bisphenol A [ 204 , 205 , 206 ]. Emerging contaminants are compounds derived from manufactured chemicals and that despite being present only in µg/L concentrations (or below) in water bodies are known to have strong impact on health and environment [ 207 ].…”
Section: Cnt-based Sensors With Different Analytes In Watermentioning
confidence: 99%
“…Finally, references [ 76 , 203 , 204 , 205 ] address the topic of emerging contaminants with electrochemical sensors based on CNT modified carbon electrodes, through the angle of drugs and hormones [ 76 , 203 ] and of bisphenol A [ 204 , 205 , 206 ]. Emerging contaminants are compounds derived from manufactured chemicals and that despite being present only in µg/L concentrations (or below) in water bodies are known to have strong impact on health and environment [ 207 ].…”
Section: Cnt-based Sensors With Different Analytes In Watermentioning
confidence: 99%
“…The operational pH range of the constructed sensor was checked for 1.0 × 10 −3 and 1.0 × 10 −4 mol L −1 DTZ solutions over a wide pH range (1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12). The constructed sensor showed very slight potential uctuations in a pH range of 2.0-8.0 (Fig.…”
Section: Effect Of Phmentioning
confidence: 99%
“…These developed sensors have the potential to be applied to provide quick analysis, rapid responses, excellent selectivity, and inexpensive analysis. [11][12][13] All of these merits make potentiometric approaches the most favorable approach for DTZ assessment. Nanomaterials exhibit improved properties that are not observable in bulk materials.…”
Section: Introductionmentioning
confidence: 99%
“…The properties of nanocomposites have led researchers and companies to explore the use of nanocomposites in a variety of fields [48] which can be ascribed to their remarkable chemical, physical and mechanical properties. Therefore, nanocomposites are predicted to provide superior capabilities for potentiometric sensors [44,49,50]. This behavior can effectively expedite the reproducibility, stability and electrocatalytic characteristics of the sensor [51].…”
Section: Introductionmentioning
confidence: 99%