2014
DOI: 10.1142/s1793292014500660
|View full text |Cite
|
Sign up to set email alerts
|

Preparation and Electrochemical Capacitive Behavior of Graphene by Microwave Assisted Thermal Reduction of Graphite Oxide in Hydrazine Hydrate

Abstract: Graphene platelets with a large scale have been synthesized by reduction of graphene oxide (GO) in aqueous solution of hydrazine hydrate under microwave irradiation (MWI). Microstructure of the graphene was characterized by X-ray di®raction (XRD), Raman spectroscopy, atomic force microscopy (AFM) and transmission electron microscopy (TEM) together with the selected area electron di®raction (SAED). The electrochemical properties were evaluated by the analysis of cyclic voltammetry (CV) and electrochemical imped… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(1 citation statement)
references
References 28 publications
0
1
0
Order By: Relevance
“…3-4 nm. Since: (i) the sample is formed of graphene covered with variable amounts of phospholipids and is therefore a difficult sample to be analyzed by AFM due to the dependence of the AFM measurements on the roughness and cleanness of the surface, 68 (ii) the thickness of a phospholipid bilayer is around 0.4 nm, 69 (iii) stabilizers cannot touch the surface of graphene directly, 68,70 and a gap exists between phospholipids and graphene, and (iv) AFM measurements depend strongly on the substrate used for graphene deposition and are distorted by the variability of substrates, 68,71,72 these data supported the formation of fewlayer graphene, likely with not more than 2-3 layers. Fig.…”
Section: Evidence Of Graphite Exfoliationmentioning
confidence: 99%
“…3-4 nm. Since: (i) the sample is formed of graphene covered with variable amounts of phospholipids and is therefore a difficult sample to be analyzed by AFM due to the dependence of the AFM measurements on the roughness and cleanness of the surface, 68 (ii) the thickness of a phospholipid bilayer is around 0.4 nm, 69 (iii) stabilizers cannot touch the surface of graphene directly, 68,70 and a gap exists between phospholipids and graphene, and (iv) AFM measurements depend strongly on the substrate used for graphene deposition and are distorted by the variability of substrates, 68,71,72 these data supported the formation of fewlayer graphene, likely with not more than 2-3 layers. Fig.…”
Section: Evidence Of Graphite Exfoliationmentioning
confidence: 99%