Abstract: Zirconium molybdosilicate (ZrMoSi) gel prepared using 99 Mo radiotracer via peroxo route was used as a base material for 99 Mo/ 99m Tc column generator. The 99m Tc elution yield and 99 Mo breakthrough in the eluate were studied as a function of the pH-value of gel precipitation, gel drying temperature and Zr : Mo : Si molar ratio. Precipitation pH-value of 2, drying temperature of 100 ∘ C and Zr : Mo : Si molar ratio of 0.5 : 0.5 : 1 were found to be the optimum conditions achieving 99m Tc elution yield of 82%… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 26 publications
0
6
0
Order By: Relevance
“…1590 and 3370 cm À1 may be attributed to the bending and stretching vibrations of the adsorbed water molecules. [44][45][46][47] However, on calcination of the combustion products, Fig. 2(d-f), the vibrational peaks due to the organic residues disappeared.…”
Section: Ft-ir Investigationmentioning
confidence: 97%
“…1590 and 3370 cm À1 may be attributed to the bending and stretching vibrations of the adsorbed water molecules. [44][45][46][47] However, on calcination of the combustion products, Fig. 2(d-f), the vibrational peaks due to the organic residues disappeared.…”
Section: Ft-ir Investigationmentioning
confidence: 97%
“…Tc generator was used for clinical research at Brookhaven medical department, which paved the way for the first utilization of 99 Mo/ 99m Tc generators in clinical investigations at Argonne Cancer Research Hospital in 1961 (Richards, 1965;Lebowitz and Richards, 1974;Atkins, 1975). Later on, through the following seven decades, the idea was developed, and several 99 Mo/ 99m Tc generator structures were established based on the different physical and chemical behaviors of 99 Mo and 99m Tc radionuclides (Allen, 1965;Boyd, 1987;IAEA, 1995IAEA, , 2013bMaoliang, 1997;Osso and Knapp, 2011;Knapp and Baum, 2012;Mostafa et al, 2016).…”
Section: Momentioning
confidence: 99%
“…Then, the molybdate- 99 Mo matrix is precipitated from its solution as an insoluble gel material. After that, the dried precipitate is packed into a column for 99m Tc elution (Boyd, 1982a(Boyd, , 1982b(Boyd, , 1987(Boyd, , 1997Evans et al, 1987;Moore et al, 1987;El-Kolaly, 1993;IAEA, 1995;Junior et al, 1998;Monroy-Guzman et al, 2003, 2007, 2008Saraswathy et al, 2004;Davarpanah et al, 2009;Mostafa et al, 2016).…”
Section: Column Chromatographic Generatorsmentioning
confidence: 99%
“…These results are consistent with the reported data. 6,20,[50][51][52][53][54] The vibrational frequencies of the produced products are presented in Table 2. 3.1.3.…”
Section: Auto-combustion Fabrication and Characterization Of Znmn 2 Omentioning
confidence: 99%