1995
DOI: 10.1016/0142-9612(95)93113-r
|View full text |Cite
|
Sign up to set email alerts
|

Preparation and use of fibrin glue in surgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
89
0
10

Year Published

1997
1997
2014
2014

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 141 publications
(101 citation statements)
references
References 69 publications
2
89
0
10
Order By: Relevance
“…Fibrin gel was used as the cell entrapment medium (-2 mgkomposite construct). The cells (-250,000 pl-') were resuspended in fully supplemented medium (FSM = Dubelcco's modified Eagle medium (DMEM) containing 10% fetal bovine serum, 4.5 g/l glucose, 10 mM N-2-hydroxyethylpiperazine N'-2-ethane sulfonic acid (Hepes), 0.1 mM non-essential amino acids, 0.4 mM proline, 50 mg/l ascorbic acid, 100 Ulml penicillin, 100 pg/ml streptomycin, and 0.5 pg/ ml fungizone) containing bovine thrombin (1 :20 dilution of 1000 units/ ml, Johnson & Johnson, Arlington, TX) and mixed with an equal volume of bovine fibrinogen (100 mg/ml) (Sigma Chemical, St. Louis, Resenrch 20 (2002) [16][17][18][19] 17 MO) in saline solution. The polymer non-woven mesh was made from PGA (2 mm x 5 mm diameter, 60 mglml, 97% porous from Albany International Research, Mansfield, MA).…”
Section: Coniposite Fabricationmentioning
confidence: 99%
“…Fibrin gel was used as the cell entrapment medium (-2 mgkomposite construct). The cells (-250,000 pl-') were resuspended in fully supplemented medium (FSM = Dubelcco's modified Eagle medium (DMEM) containing 10% fetal bovine serum, 4.5 g/l glucose, 10 mM N-2-hydroxyethylpiperazine N'-2-ethane sulfonic acid (Hepes), 0.1 mM non-essential amino acids, 0.4 mM proline, 50 mg/l ascorbic acid, 100 Ulml penicillin, 100 pg/ml streptomycin, and 0.5 pg/ ml fungizone) containing bovine thrombin (1 :20 dilution of 1000 units/ ml, Johnson & Johnson, Arlington, TX) and mixed with an equal volume of bovine fibrinogen (100 mg/ml) (Sigma Chemical, St. Louis, Resenrch 20 (2002) [16][17][18][19] 17 MO) in saline solution. The polymer non-woven mesh was made from PGA (2 mm x 5 mm diameter, 60 mglml, 97% porous from Albany International Research, Mansfield, MA).…”
Section: Coniposite Fabricationmentioning
confidence: 99%
“…Nowadays, the most used surgical adhesives are based on fibrin [3,4] and cyanoacrylates [5,6]. The fibrin based adhesives present several problems, e.g.…”
Section: Introductionmentioning
confidence: 99%
“…Entretanto, o uso da cola reduziu o número de suturas e conseqüentemente o tempo cirúrgico (Saltz et al, 1991;Silver et al, 1995;Stolf, 1998), fato bastante significativo em pacientes de alto risco.…”
Section: Discussionunclassified
“…Aplicada no enxerto e em suas margens, auxilia tanto na fixação deste como na hemostasia da ferida. Ela tem sido usada para eliminar o espaço morto e aumentar a probabilidade de o enxerto ser revascularizado e diminuir o número de suturas em cirurgias cosméticas e reconstrutivas (Silver et al, 1995).…”
Section: Introductionunclassified