2011
DOI: 10.1016/j.aca.2011.02.056
|View full text |Cite
|
Sign up to set email alerts
|

Preparation, characterization and application of organic–inorganic hybrid ractopamine multi-template molecularly imprinted capillary monolithic column

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
40
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 48 publications
(40 citation statements)
references
References 18 publications
0
40
0
Order By: Relevance
“…In addition, the effects of electroosmotic flow (EOF) and selectivity were also studied. 502 Owing to the advantages of simple column preparation, no bubble formation and stable EOF application, opentubular CEC (OT-CEC)-based MIP columns are potential tools for the specific recognition of enantiomers among the various forms used in CEC. 503 Moon et al used an OT-CEC column with a monolithic MIP layer for simultaneous separation and characterization of phospholipid (PL) molecular structures by electrospray ionization-tandem mass spectrometry (ESI-MS/MS).…”
Section: Monolithic Column Materials For Chromatographymentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, the effects of electroosmotic flow (EOF) and selectivity were also studied. 502 Owing to the advantages of simple column preparation, no bubble formation and stable EOF application, opentubular CEC (OT-CEC)-based MIP columns are potential tools for the specific recognition of enantiomers among the various forms used in CEC. 503 Moon et al used an OT-CEC column with a monolithic MIP layer for simultaneous separation and characterization of phospholipid (PL) molecular structures by electrospray ionization-tandem mass spectrometry (ESI-MS/MS).…”
Section: Monolithic Column Materials For Chromatographymentioning
confidence: 99%
“…502 The prepared imprinting capillary monolithic column was evaluated with CEC for the recognition of ractopamine. In addition, the effects of electroosmotic flow (EOF) and selectivity were also studied.…”
Section: Monolithic Column Materials For Chromatographymentioning
confidence: 99%
“…Hence, NHSG hybrids can subtly increase the selectivity of the hybrid monolithic MIPs [103]. Similarly, a MIP hybrid monolith was also prepared by using acrylamide and ␥-MAPS as precursors, methanol and toluene as porogenic solvents, AIBN as initiator, as well as four isomers of ractopamine as multitemplate molecule [104]. The imprinted hybrid monolith had good selectivity for four isomers of ractopamine, and four isomers of ractopamine could be separated completely in CEC under the optimal conditions.…”
Section: Microscale Separationmentioning
confidence: 99%
“…According to He et al, 31 the permeability of MIP columns can be divided into following three groups with the pressure at 1 MPa: better permeability if the mobile phase flows out in 30 s, good permeability if it takes 30 s-1 min, and poor permeability if it takes more than 1 min. The results are illustrated in Table I.…”
Section: Preparation Of Mip Monolithic Columnsmentioning
confidence: 99%
“…It controls the speed and direction of the sample movement, and also affects the separation efficiency and reproducibility. 31 In this study, thiourea was used to characterize the EOF of the prepared MIP monolithic columns. Voltage is one of the most important factors for controlling the speed and direction of EOF.…”
Section: Eof Of the Mip Monolithic Columnsmentioning
confidence: 99%