2010
DOI: 10.1007/s10967-010-0732-0
|View full text |Cite
|
Sign up to set email alerts
|

Preparation of 26Al, 59Ni, 44Ti, 53Mn and 60Fe from a proton irradiated copper beam dump

Abstract: The station for pions cancer therapy was operated at PSI from 1980 to 1992. After a cooling time of 12 years it's made of copper beam dump was cut and samples were taken for analytical purposes. The sampling collected about 500 g of high active copper chips that can be used for separation of exotic radionuclides. The analyses by gamma spectrometry, LSC and AMS showed main nuclides present to be 60 Ti with a daughter nuclide 44 Sc. In the frame of ERAWAST project a procedure combining selective precipitation … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…Hence, chemical techniques have to be applied in order to separate interfering nuclides. Several examples to separate 44 Ti/ 44 Sc from radioactive waste are described in literature [10,23,24]. This task will be faced in future work.…”
Section: Resultsmentioning
confidence: 99%
“…Hence, chemical techniques have to be applied in order to separate interfering nuclides. Several examples to separate 44 Ti/ 44 Sc from radioactive waste are described in literature [10,23,24]. This task will be faced in future work.…”
Section: Resultsmentioning
confidence: 99%
“…the abundance of ( 171 Tm + 171 Yb) in the used solution, was measured 8 times by HR-ICP-MS using an Element 2, Thermo-Fischer Scientific, Bremen, Germany, operated in low resolution mode and wet plasma conditions. A secondary calibration source was prepared from a purified stock solution 44 Ti/ 44 Sc available from earlier experiments [11]. An aliquot of this stock solution was diluted with MilliQ water to yield a solution containing approx.…”
Section: Methodsmentioning
confidence: 99%
“…A secondary calibration source was prepared from a purified stock solution 44 Ti/ 44 Sc available from earlier experiments [11]. An aliquot of this stock solution was diluted with MilliQ water to yield a solution containing approx.…”
Section: Methodsmentioning
confidence: 99%
“…The purified 53 Mn fraction [20] in the form of an acidic chloride solution was evaporated to dryness and redissolved in approx. 0.5 mL 1 M HCl.…”
Section: A Sample Productionmentioning
confidence: 99%