1965
DOI: 10.1016/0009-8981(65)90211-1
|View full text |Cite
|
Sign up to set email alerts
|

Preparation of a cam for the scanning of paper electropherograms on the chromoscan densitometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

1966
1966
1970
1970

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 8 publications
0
3
0
Order By: Relevance
“…The fractions were determined by the elution method of Webster (1965) and also by densitometry using a Joyce-Loebl chromoscan. Cams provided with the instrument were found to underestimate albumin concentration, but no attempt was made to construct a linearising cam analogous to that of Kenny (1965) because satisfactory results were obtained for the globulin fractions. Most of the cellulose acetate studies employed Oxoid (Oxoid, London) 2.5 x 12 COl strips, but later smaller 'microzone' strips (Beckman Instruments, Glenrothes) were evaluated by densitometry.…”
Section: Methods Which Give Albumin and Globulin Valuesmentioning
confidence: 98%
See 1 more Smart Citation
“…The fractions were determined by the elution method of Webster (1965) and also by densitometry using a Joyce-Loebl chromoscan. Cams provided with the instrument were found to underestimate albumin concentration, but no attempt was made to construct a linearising cam analogous to that of Kenny (1965) because satisfactory results were obtained for the globulin fractions. Most of the cellulose acetate studies employed Oxoid (Oxoid, London) 2.5 x 12 COl strips, but later smaller 'microzone' strips (Beckman Instruments, Glenrothes) were evaluated by densitometry.…”
Section: Methods Which Give Albumin and Globulin Valuesmentioning
confidence: 98%
“…Electrophoresis was done on paper and cellulose acetate. Lissamine green was used as dye for paper electrophoresis and then the strips were scanned using a Joyce-Loebl chromoscan (Joyce, Loebl and Co. Ltd., Team Valley, Gateshead) with a modified cam (Kenny, 1965).…”
Section: Methods Which Give Albumin and Globulin Valuesmentioning
confidence: 99%
“…There are a number of examples of apparatus developed for use in conjunction with electrophoresis, such as an incubator for measuring enzymes (1223), a fraction collector for low temperature columns (200), and devices for electrical destaining (1833,2008). Commercial densitometers have been improved (313, 1114), spectrophotometers have been modified for densitometry (1573, 2185), and designs have been suggested for scanning (1048), integrating (1347), and recording (1728) densitometers.…”
Section: Apparatusmentioning
confidence: 99%