SUMMARYApplying anticorrosion grease and aluminum-clad steel (AC) wires to ACSR have been adopted as general methods to protect overhead transmission line conductors and/or wires from corrosion. However, in some cases those means have been found to be ineffective on some transmission lines passing through acid atmosphere in the vicinity of a factory exhausting acid smoke. The corrosion caused by acid atmosphere is characterized by a higher speed in its progress as is well known.As means against such acid corrosion, application of high-purity aluminum, selective removal of intermetallic compound in aluminum, and plastic coating wires have been reported before, and each has both advantages and disadvantages. In a former report, we found that a new type of anticorrosion grease shows an excellent property against acid atmosphere as well as in a salty condition.Here we present a new type of anticorrosion technology of applying high-corrosion-resistance aluminum alloy or zinc coatings on each component wire of a conductor that we succeeded in developing through a serial study of anticorrosion methods on overhead transmission lines.