2020
DOI: 10.1007/s00604-020-04483-5
|View full text |Cite
|
Sign up to set email alerts
|

Preparation of electrospun polyacrylonitrile/Ni-MOF-74 nanofibers for extraction of atenolol and captopril prior to HPLC-DAD

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 49 publications
(10 citation statements)
references
References 40 publications
0
9
0
Order By: Relevance
“…The FTIR spectra of all the samples including Ni-MOF-74 powder, MWCNT, PAN/MWCNT, PAN/MOF, and PAN/MWCNT/MOF nanofibers are shown in Figure 13 . In the Ni-MOF-74 spectrum, the characteristic peaks at around 1558, 1419 cm −1 are ascribed to stretching vibrations of symmetric and asymmetric carboxylate groups (–COO–) [ 59 ]. Moreover, the peaks are located at 920, 850, and 3415 cm −1 , which are attributed to stretching vibration of Ni–O, C–H, and –OH bonds, respectively [ 58 ].…”
Section: Resultsmentioning
confidence: 99%
“…The FTIR spectra of all the samples including Ni-MOF-74 powder, MWCNT, PAN/MWCNT, PAN/MOF, and PAN/MWCNT/MOF nanofibers are shown in Figure 13 . In the Ni-MOF-74 spectrum, the characteristic peaks at around 1558, 1419 cm −1 are ascribed to stretching vibrations of symmetric and asymmetric carboxylate groups (–COO–) [ 59 ]. Moreover, the peaks are located at 920, 850, and 3415 cm −1 , which are attributed to stretching vibration of Ni–O, C–H, and –OH bonds, respectively [ 58 ].…”
Section: Resultsmentioning
confidence: 99%
“…6). The matrix effect (ME%) was calculated based on the analytical signals obtained in non-spiked and spiked samples using the following equation: 36 where A s , A n , and A w correspond to the peak area of the analyte in the spiked samples, non-spiked samples, and spiked ultra-pure water, respectively. As shown in Table 2, no significant matrix effect was observed in the analysis of target drugs in real water samples.…”
Section: Resultsmentioning
confidence: 99%
“…11 Consequently, micro-solid phase extractionpipette tip (PT-SPE) has emerged as a modern, cost-effective, rapid, effective, and environmentally friendly method for preconcentrating diverse analytes including drugs, peptides, and proteins. [12][13][14] In the PT-SPE technique, the amount of adsorbents applied in the pipette tip and the use of harmful organic solvents are significantly reduced. 15,16 However, despite the above-mentioned features, the PT-SPE technique has little capacity for extraction.…”
Section: Introductionmentioning
confidence: 99%