Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Purpose Our aim was to assess the different voice prostheses (VPs) to identify the most efficient, safest, patient-tailored, longest lifetime, and inexpensive VPs and assess the different factors affecting their quality. Method In September 2017, 15 databases were searched to include all randomized controlled trials. A new search was done in May 2019 to include all other study design articles, which include all the new-era VPs subtypes. Network meta-analysis (NMA) was applied to all 27 outcomes, besides NMA overall and partial order setting was done by using Hasse scatter plots. p values were used in NMA, where the best VPs are approaching one and the least approaches zero. Meta-analysis was done for the rest of the outcomes. Results Two hundred one articles were eligible for inclusion in our study ( N = 11,918). Provox-2 was significantly the most efficient and safest device concerning the most patient preference (odds ratio [ OR ] = 33.88 [0.65, 1762.24]; p = .92), the least dislodgement (risk ratio [RR] = 0.27 [0.13, 0.57]; p = .79), the least airflow resistance (RR = 0.42 [0.08, 2.11]; p = .84), the least granulation formation (RR = 0.73 [0.02, 26.32]; p = .60), and the least VPs' inaccurate size (RR = 0.77 (0.23, 2.61); p = .66). Heat and moisture exchanger addition showed a significant increase in maximum phonation time and breathing experience, with p values (1 and .59), respectively. While heat and moisture exchanger addition showed a significant decline in stoma cleaning frequency, coughing frequency, forced expectoration, sputum production, sleeping problems, and loosening of adhesive, with p values (.99, .72, .69, .96, 1, and 0.96), respectively, Groningen low resistance and Nijdam were considered the worst devices with both overall mean p value of .44. Conclusions Provox-2 is considered the best choice as being the most preferable for patients, with the least airflow resistance, dislodgment, granulation formation, and prosthesis inaccurate size. Groningen low resistance and Nijdam were considered the worst devices according to our analysis. Supplemental Material https://doi.org/10.23641/asha.14802903
Purpose Our aim was to assess the different voice prostheses (VPs) to identify the most efficient, safest, patient-tailored, longest lifetime, and inexpensive VPs and assess the different factors affecting their quality. Method In September 2017, 15 databases were searched to include all randomized controlled trials. A new search was done in May 2019 to include all other study design articles, which include all the new-era VPs subtypes. Network meta-analysis (NMA) was applied to all 27 outcomes, besides NMA overall and partial order setting was done by using Hasse scatter plots. p values were used in NMA, where the best VPs are approaching one and the least approaches zero. Meta-analysis was done for the rest of the outcomes. Results Two hundred one articles were eligible for inclusion in our study ( N = 11,918). Provox-2 was significantly the most efficient and safest device concerning the most patient preference (odds ratio [ OR ] = 33.88 [0.65, 1762.24]; p = .92), the least dislodgement (risk ratio [RR] = 0.27 [0.13, 0.57]; p = .79), the least airflow resistance (RR = 0.42 [0.08, 2.11]; p = .84), the least granulation formation (RR = 0.73 [0.02, 26.32]; p = .60), and the least VPs' inaccurate size (RR = 0.77 (0.23, 2.61); p = .66). Heat and moisture exchanger addition showed a significant increase in maximum phonation time and breathing experience, with p values (1 and .59), respectively. While heat and moisture exchanger addition showed a significant decline in stoma cleaning frequency, coughing frequency, forced expectoration, sputum production, sleeping problems, and loosening of adhesive, with p values (.99, .72, .69, .96, 1, and 0.96), respectively, Groningen low resistance and Nijdam were considered the worst devices with both overall mean p value of .44. Conclusions Provox-2 is considered the best choice as being the most preferable for patients, with the least airflow resistance, dislodgment, granulation formation, and prosthesis inaccurate size. Groningen low resistance and Nijdam were considered the worst devices according to our analysis. Supplemental Material https://doi.org/10.23641/asha.14802903
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.