2019
DOI: 10.1016/j.arth.2019.07.007
|View full text |Cite
|
Sign up to set email alerts
|

Primary Total Knee Arthroplasty Implants as Functional Prosthetic Spacers for Definitive Management of Periprosthetic Joint Infection: A Multicenter Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
34
1
5

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 31 publications
(40 citation statements)
references
References 49 publications
0
34
1
5
Order By: Relevance
“…Raut et al revealed 84% eradication rate [53] and 86% eradication rate in patients with sinus tracts [10] at 7-year follow-up in THA. As for TKA, Siddiqi et al [54] recently reported an 86% eradication rate and 80.7% surgery-free survival rate at 5-year follow-up in patients receiving cemented all-polyethylene tibia components. Table 2 lists current studies on outcomes following single-stage exchange.…”
Section: Single-stage Exchange Arthroplastymentioning
confidence: 99%
“…Raut et al revealed 84% eradication rate [53] and 86% eradication rate in patients with sinus tracts [10] at 7-year follow-up in THA. As for TKA, Siddiqi et al [54] recently reported an 86% eradication rate and 80.7% surgery-free survival rate at 5-year follow-up in patients receiving cemented all-polyethylene tibia components. Table 2 lists current studies on outcomes following single-stage exchange.…”
Section: Single-stage Exchange Arthroplastymentioning
confidence: 99%
“…1 CD). For knees, two types of spacers were also used [13][14][15] : for type I, an aseptic silicone mold imitating the joint shape was used, and a joint-like spacer was made intraoperatively ( Fig. 1 EF); for type II, the removed femoral end prosthesis was washed, soaked in povidone iodine solution and resterilized, and the resterilized tibial prosthesis was used or replaced with a new polyethylene tibial component ( Fig.…”
Section: The Process Of Revision Surgery and Preparation Of Joint Spamentioning
confidence: 99%
“…For type II, 105 mm femoral stem, 28 mm femoral head and 32 mm femoral neck (CM-CZ; AK Medical, Beijing, China) were used as scaffolds, which were embedded with antibiotic-impregnated cement and molded under pressure (Fig 1 CD). For knees, two types of spacers were also used [13][14][15] : for type I, an aseptic silicone mold imitating the joint shape was used, and a joint-like spacer was made intraoperatively (Fig 1 EF); for type II, the removed femoral end prosthesis was washed, soaked in povidone iodine solution and resterilized, and the resterilized tibial prosthesis was used or replaced with a new polyethylene tibial component (Fig 1 GH). The antibiotics used in the antibiotic-impregnated joint spacer were selected according to the microbial culture and drug sensitivity test results.…”
Section: The Process Of Revision Surgery and Preparation Of Joint Spamentioning
confidence: 99%