2020
DOI: 10.1021/acs.jpca.0c04195
|View full text |Cite
|
Sign up to set email alerts
|

Probing Sulfur Chemical and Electronic Structure with Experimental Observation and Quantitative Theoretical Prediction of Kα and Valence-to-Core Kβ X-ray Emission Spectroscopy

Abstract: An extensive experimental and theoretical study of the Kα and Kβ high-resolution X-ray emission spectroscopy (XES) of sulfur-bearing systems is presented. This study encompasses a wide range of organic and inorganic compounds, including numerous experimental spectra from both prior published work and new measurements. Employing a linear-response time-dependent density functional theory (LR-TDDFT) approach, strong quantitative agreement is found in the calculation of energy shifts of the core-to-core Kα as well… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
39
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 37 publications
(44 citation statements)
references
References 151 publications
4
39
1
Order By: Relevance
“…An average Bragg angle of 58.9 degrees ensures that the correct energy range is projected onto the detector plane. This spectrometer has been previously used for studies of oxidation state and more complex electronic structure for sulfur and phosphorus compounds showing excellent agreement with synchrotron results, including for the reference compounds used here and cited below 11,21,44,45 …”
Section: Methodsmentioning
confidence: 69%
See 2 more Smart Citations
“…An average Bragg angle of 58.9 degrees ensures that the correct energy range is projected onto the detector plane. This spectrometer has been previously used for studies of oxidation state and more complex electronic structure for sulfur and phosphorus compounds showing excellent agreement with synchrotron results, including for the reference compounds used here and cited below 11,21,44,45 …”
Section: Methodsmentioning
confidence: 69%
“…Unlike XANES, which requires synchrotron access when the species of interest is dilute, nonresonant XES can be performed with lab‐based equipment even for relatively dilute systems 11,33,34 . We find that the sulfur content in several cementitious materials relevant for CWFs is sufficient for relatively rapid in‐house measurement of the S Kα XES, and that the resulting spectra can be fit with high precision to reference standards when allowing an additional fit parameter for small shifts in the nominal Kα 1 location due to chemical effects within the same nominal oxidation state 21,22 …”
Section: Introductionmentioning
confidence: 96%
See 1 more Smart Citation
“…4d / 2p transitions are calculated for the relaxed 2p- To analyze the character of the spectral features, we utilize a previously described weighting scheme. 73 Aer identifying the most dominant transitions within a specic energy range (i.e. the transitions of peaks a, b, c), we decompose their valence molecular orbitals contributions into weighted sums of atomic orbitals.…”
Section: Non-resonant Ru L 3 -Edge Vtc X-ray Emissionmentioning
confidence: 99%
“…In recent years, Kβ X-ray emission spectroscopy (XES) has become a more frequently used technique, with a focus on 3d transition metals. [40][41][42][43][44][45][46] Some work has also been performed on 4d elements, [47][48][49] and sulfur Kβ X-ray emission has been somewhat explored, [50][51][52][53][54] including a study of the protonation state of aqueous sulfate, 55 but very few Kβ XES studies of phosphorus have been reported. 50,[56][57][58] Phosphorus Kβ X-ray emission spectroscopy (XES) has great potential as a probe of phosphorus in both molecular and biological systems, promising rich electronic structural information and compatibility with diverse sample preparations that would augment existing techniques.…”
Section: Introductionmentioning
confidence: 99%