X-Ray, Optical, and Infrared Detectors for Astronomy IX 2020
DOI: 10.1117/12.2560339
|View full text |Cite
|
Sign up to set email alerts
|

Processing x-ray data on board the SMILE SXI

Abstract: SMILE (Solar Magnetosphere Ionosphere Link Explorer) is a collaborative mission between the European Space Agency and the Chinese Academy of Sciences that is scheduled to be launched in 2024 and will be placed in a highly elliptical, inclined, orbit. The on-board instrumentation will study interactions between the solar wind and the Earth's magnetosphere-ionosphere system by imaging the soft X-ray emission that results from solar wind charge exchange whilst simultaneously collecting information about the north… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 6 publications
0
3
0
Order By: Relevance
“…It aimed to predict and analyse the effect of charge spreading on the additional uncertainty introduced into X-ray interaction event reconstruction in various X-ray detector architectures. This model uses a simplified version of the two threshold reconstruction technique commonly used for space based detectors [7,9]. In this process:…”
Section: Jinst 19 P05017 2 Reconstruction Uncertainty Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…It aimed to predict and analyse the effect of charge spreading on the additional uncertainty introduced into X-ray interaction event reconstruction in various X-ray detector architectures. This model uses a simplified version of the two threshold reconstruction technique commonly used for space based detectors [7,9]. In this process:…”
Section: Jinst 19 P05017 2 Reconstruction Uncertainty Modelmentioning
confidence: 99%
“…In addition, pattern matching is often used as a prelude to X-ray event grading, which is not always an option for low flux applications. The reconstruction and detection thresholds for a detector are often set in relation to the per-pixel expected noise, values three to five times the per-pixel rms noise are common (for example, [9,10]). This approach addresses the consequence of including too many noisy pixels during reconstruction but may ignore the effect of sub-threshold pixels containing charge.…”
Section: Jinst 19 P05017 2 Reconstruction Uncertainty Modelmentioning
confidence: 99%
“…The X-ray event threshold for a particular detector is often a multiple of the per pixel rms noise above the zero value (for example, 11 ). This is selected to ensure maximum detectability of X-rays whilst suppressing the number of noisy pixels falsely identified as X-rays.…”
Section: Detectabilitymentioning