2010
DOI: 10.1016/j.nima.2009.11.045
|View full text |Cite
|
Sign up to set email alerts
|

Production and quality control of STAR-TOF MRPC

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
20
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 26 publications
(20 citation statements)
references
References 5 publications
0
20
0
Order By: Relevance
“…Tsinghua University is in charge of a majority of the MRPC production. To assure the quality of MRPC modules, a rigid set of manufacturing criteria and quality assurance (QA) procedures [29] are set up. Specifications of the dimensions and materials have been controlled strictly, and the characteristics such as dark current, noise rate, efficiency and time resolution have been validated.…”
Section: The Star-tof Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…Tsinghua University is in charge of a majority of the MRPC production. To assure the quality of MRPC modules, a rigid set of manufacturing criteria and quality assurance (QA) procedures [29] are set up. Specifications of the dimensions and materials have been controlled strictly, and the characteristics such as dark current, noise rate, efficiency and time resolution have been validated.…”
Section: The Star-tof Systemmentioning
confidence: 99%
“…This detector is easy to build and possible to cover a large area. It has been extensively employed as a ToF system in many nuclear physics experiments, such as BESIII [21], ALICE [22][23][24], CBM [25,26], STAR [27][28][29] and PHENIX [30].…”
Section: Introductionmentioning
confidence: 99%
“…3 Mass production for STAR-MTD 6 3.1 New cosmic-ray test system with long scintillators 6 3.2 Status of mass production for STAR-MTD 7 1 Introduction…”
Section: Jinst 7 P10006mentioning
confidence: 99%
“…The method of time of flight (TOF) plays and important role in the identification of proton, kaon and pion. With the development of gas detectors, the Multi-gap Resistive Plate Chambers (MRPC) have been used to construct the TOF system such as RHIC-STAR, LHC-ALICE and et al [1,2]. The MRPC technology TOF system can be generalized as three generation.…”
Section: Introductionmentioning
confidence: 99%
“…For the second generation TOF, its time resolution is in the same order with the first generation, but the rate capability is much higher. The typical experiment with this high rate TOF is FAIR-CBM and its rate requirement can reach 30kHz/cm 2 .The biggest challenge is on the third generation TOF. For example, the momentum upper limit of K/PI separation is around 7GeV/c for JLab-SoLID TOF system under high particle rate as high as 20kHz/cm 2 , the time resolution requirement is around 20ps.…”
Section: Introductionmentioning
confidence: 99%